  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 380-500 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 205 A 380-500V IP00 - 136X7470
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136X7470
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136X7470

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 205 A 380-500V IP00 - 136X7470

Send inquiry Order code: 136X7470
(You save )
Brand
VACON
SKU:
136X7470
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Rated current (A):
205
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH05
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA02055-A0T02WV-A1A20000CP

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136X7470 and type code NXA02055-A0T02WV-A1A20000CP is a 205 A, three-phase 380-500 V supply, IP00 enclosure, frame CH05 configuration. It is rated 205 A continuous output current and meets EMC category C4.

Key specifications

Order code136X7470
Type codeNXA02055-A0T02WV-A1A20000CP
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated current205 A
Current, high overload137 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH05
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)553 x 246 x 264 mm
Net weight40 kg
EAN5714853158812

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0205205 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot ECPPROFINET
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH05Frame 05 liquid cooled
Motor Power Low Overload [kW]XXXXXX
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X553X264246X553X264
Continuous Current (NO) [A]215215
Continuous Current (HO) [A]137137
Calculated Package Weight1

Typical applications

This configuration, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: PROFINET.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 136X7470 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H4111

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 205 A 380-500V IP00 - 132H4111

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H4111 and type code NXA02055-A0T02WG-A1A20000E6 is a 205 A, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N0129

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 631 kW 380-500V IP00 - 137N0129

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N0129 and type code NXA10305-A0T02WG-A1A2000000+FL23+ARFIFF05+GSNT+DLDE+LPC2+SPXE is a 631 kW,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U7982

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137U7982

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U7982 and type code NXA02055-A0T02WG-A1A2D7B5E9+MASG+ARFIFF03 is a 125 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U2739

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 319 kW 380-500V IP00 - 137U2739

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U2739 and type code NXA05205-A0T02WG-A1B1B8B8E9+ARFIFF05+DLES+GABV+LPC2 is a 319 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X1309

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 137X1309

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X1309 and type code NXA11505-A0T02WG-A1B1BH00E9+EMAR is a 704 kW, three-phase 380-500 V supply, IP00...