VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X1309

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 137X1309

Send inquiry Order code: 137X1309
(You save )
Brand
VACON
SKU:
137X1309
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
704
Rated current (A):
1150
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA11505-A0T02WG-A1B1BH00E9+EMAR

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X1309 and type code NXA11505-A0T02WG-A1B1BH00E9+EMAR is a 704 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63 configuration. It is rated 1150 A continuous output current and meets EMC category C4.

Key specifications

Order code137X1309
Type codeNXA11505-A0T02WG-A1B1BH00E9+EMAR
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power704 kW
Rated current1150 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5715253799339

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current11501150 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BB16 programmableDI/DO
Option Slot CBH3 temp meas channels
Option Slot D00No board
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+EMARMarine Approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]704704
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]10451045
Continuous Current (HO) [A]--

Typical applications

At 704 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 6 programmableDI/DO; slot C: 3 temp meas channels; slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137X1309 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N0132

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 137N0132

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N0132 and type code NXA11505-A0T02WG-A1A2000000+FL23+ARFIFF05+GSNT+DLDE+LPC2+SPXE is a 704 kW,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136U0470

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 136U0470

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136U0470 and type code NXA11505-A0T02PG-A1A2D7BHE9+MASG+ARFIFF03+GABV is a 704 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137G5466

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 137G5466

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137G5466 and type code NXA11505-A0T02WG-A1A2D7B5E9+ARFIFF03+DLCN is a 704 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137G6990

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 137G6990

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137G6990 and type code NXA11505-A0T02WG-A1A2D7B5E9+GRDC+ARFIF106+DLCN is a 704 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N6702

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 704 kW 380-500V IP00 - 132N6702

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N6702 and type code NXA11505-A0T02WG-A1A2D700E6+MASG+ARFIFF03 is a 704 kW, three-phase 380-500 V...