  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 380-500 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137U7982
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U7982
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U7982

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137U7982

Send inquiry Order code: 137U7982
(You save )
Brand
VACON
SKU:
137U7982
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
125
Rated current (A):
205
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH05
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA02055-A0T02WG-A1A2D7B5E9+MASG+ARFIFF03

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U7982 and type code NXA02055-A0T02WG-A1A2D7B5E9+MASG+ARFIFF03 is a 125 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05 configuration. It is rated 205 A continuous output current and meets EMC category C4.

Key specifications

Order code137U7982
Type codeNXA02055-A0T02WG-A1A2D7B5E9+MASG+ARFIFF03
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power125 kW
Rated current205 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH05
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)553 x 246 x 264 mm
Net weight40 kg
EAN5715253764948

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0205205 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot DB53RO(NO)
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software license+MASGGrid Converter license
Application+ARFIFF03Grid Converter NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH05Frame 05 liquid cooled
Motor Power Low Overload [kW]125125
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X553X264246X553X264
Continuous Current (NO) [A]186186
Continuous Current (HO) [A]--
customized ID+BM26+BM26

Typical applications

At 125 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot D: 3RO(NO); slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137U7982 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N5668

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 136N5668

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N5668 and type code NXA02055-A0T02WG-A1A2D7B5CI is a 125 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H9652

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137H9652

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H9652 and type code NXA02055-A0T02PV-A1A2B500EC+FL23+GRID+ARFIF106+DLDE is a 125 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2598

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137L2598

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2598 and type code NXA02055-A0T02WG-A1B8D700E9+MASG+ARFIFF03 is a 125 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H4449

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137H4449

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H4449 and type code NXA02055-A0T02WG-A9A20000CP+ARFIFF05 is a 125 kW, three-phase 380-500 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U6827

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137U6827

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U6827 and type code NXA02055-A0T02PG-A1A2B40000 is a 125 kW, three-phase 380-500 V supply, IP00...