  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132N0760
  • VACON NXP Common DC Bus Brake Chopper Unit 132N0760
VACON NXP Common DC Bus Brake Chopper Unit 132N0760

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132N0760

Send inquiry Order code: 132N0760
(You save )
Brand
VACON
SKU:
132N0760
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
140
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR08
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB01405-A2T08SV-A1A2000000+FL23+DLDE

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 132N0760 and type code NXB01405-A2T08SV-A1A2000000+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It is rated 140 A continuous output current and meets EMC category C4.

Key specifications

Order code132N0760
Type codeNXB01405-A2T08SV-A1A2000000+FL23+DLDE
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current140 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP21/NEMA1
Frame sizeFR08
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Net weight48 kg
EAN5715253045559

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0140140 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLDEGerman
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]2X892X89
Motor Power High Overload [kW]--
Continuous Current (NO) [A]2X1402X140
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 132N0760 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 132H2906

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H2906

The VACON NXP Common DC Bus brake chopper unit with order code 132H2906 and type code NXB01055-A2T08SV-A1B100B8E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132H5087

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H5087

The VACON NXP Common DC Bus brake chopper unit with order code 132H5087 and type code NXB00725-A2T08SV-A8A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132H7210

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H7210

The VACON NXP Common DC Bus brake chopper unit with order code 132H7210 and type code NXB00315-A2T08SV-A1A20000EA+QGLM+ABGEW123 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Brake Chopper Unit 132X1662

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132X1662

The VACON NXP Common DC Bus brake chopper unit with order code 132X1662 and type code NXB00045-A2T08SV-A1A2000000+FL21 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Common DC Bus Brake Chopper Unit 136X9641

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136X9641

The VACON NXP Common DC Bus brake chopper unit with order code 136X9641 and type code NXB00875-A2T08SV-A1A20000E9+QGLM+FL23+DLNL is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...