VACON NXP Common DC Bus Brake Chopper Unit 132H7210

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H7210

Send inquiry Order code: 132H7210
(You save )
Brand
VACON
SKU:
132H7210
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
31
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR06
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB00315-A2T08SV-A1A20000EA+QGLM+ABGEW123

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 132H7210 and type code NXB00315-A2T08SV-A1A20000EA+QGLM+ABGEW123 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It is rated 31 A continuous output current and meets EMC category C4.

Key specifications

Order code132H7210
Type codeNXB00315-A2T08SV-A1A20000EA+QGLM+ABGEW123
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current31 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP21/NEMA1
Frame sizeFR06
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Net weight16 kg
EAN5714853363179

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current003131 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLMMetric conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot EEAAdvanced 2-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABGEW123Appl sw ABGEW123 NXP, NXI
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR06Frame 06
Motor Power Low Overload [kW]2X202X20
Motor Power High Overload [kW]--
Continuous Current (NO) [A]2X312X31
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: Advanced 2-port ethernet.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 132H7210 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 137H9361

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137H9361

The VACON NXP Common DC Bus brake chopper unit with order code 137H9361 and type code NXB00725-G2T08SV-A1A200E900+QGLM+GADN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 137U4852

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U4852

The VACON NXP Common DC Bus brake chopper unit with order code 137U4852 and type code NXB00045-A2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137G6229

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G6229

The VACON NXP Common DC Bus brake chopper unit with order code 137G6229 and type code NXB00725-A2T08SV-A1A20000E6 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137X0750

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137X0750

The VACON NXP Common DC Bus brake chopper unit with order code 137X0750 and type code NXB01055-A2T08SV-A1A2000000+QGLM is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 137G8398

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G8398

The VACON NXP Common DC Bus brake chopper unit with order code 137G8398 and type code NXB00725-A2T08SV-A1A20000E6+DLNL is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...