  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 525-690 V
  • VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137X2306
  • VACON NXP Common DC Bus Brake Chopper Unit 137X2306
VACON NXP Common DC Bus Brake Chopper Unit 137X2306

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137X2306

Send inquiry Order code: 137X2306
(You save )
Brand
VACON
SKU:
137X2306
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
208
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FI09
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXB02086-G0T08SG-A8A30000E9+GADN

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 137X2306 and type code NXB02086-G0T08SG-A8A30000E9+GADN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It is rated 208 A continuous output current and meets EMC category C4.

Key specifications

Order code137X2306
Type codeNXB02086-G0T08SG-A8A30000E9+GADN
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current208 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
EnclosureIP00
Frame sizeFI09
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)1030 x 239 x 372 mm
Net weight67 kg
EAN5715253809557

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0208208 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot C00No board
Option Slot D00No board
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GADNNorskeVeritas&GermanischeLloyd
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI09Frame 09 INU
Motor Power Low Overload [kW]2X2282X228
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X372239X1030X372
Continuous Current (NO) [A]2X2082X208
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 1RO(NO/NC),1RO(NC), therm; slot E: 2-port ethernet.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 137X2306 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 137X1300

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137X1300

The VACON NXP Common DC Bus brake chopper unit with order code 137X1300 and type code NXB01006-A0T08SV-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132H7183

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132H7183

The VACON NXP Common DC Bus brake chopper unit with order code 132H7183 and type code NXB01006-A0T08SV-A1A20000C5 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132L9815

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132L9815

The VACON NXP Common DC Bus brake chopper unit with order code 132L9815 and type code NXB03856-A0T08SG-A1A3000000+FL24 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 136N4794

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 136N4794

The VACON NXP Common DC Bus brake chopper unit with order code 136N4794 and type code NXB01706-A0T08SG-A1A20000E9 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137H8936

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137H8936

The VACON NXP Common DC Bus brake chopper unit with order code 137H8936 and type code NXB03256-A0T08SG-A1A20000E9 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...