  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 525-690 V
  • VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132H7183
  • VACON NXP Common DC Bus Brake Chopper Unit 132H7183
VACON NXP Common DC Bus Brake Chopper Unit 132H7183

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132H7183

Send inquiry Order code: 132H7183
(You save )
Brand
VACON
SKU:
132H7183
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
100
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FR08
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB01006-A0T08SV-A1A20000C5

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 132H7183 and type code NXB01006-A0T08SV-A1A20000C5 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08 configuration. It is rated 100 A continuous output current and meets EMC category C4.

Key specifications

Order code132H7183
Type codeNXB01006-A0T08SV-A1A20000C5
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current100 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
EnclosureIP00
Frame sizeFR08
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Net weight58 kg
EAN5714853362677

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0100100 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot EC5PROFIBUS DP Sub-D9, Spare only
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]2X1092X109
Motor Power High Overload [kW]--
Continuous Current (NO) [A]2X1002X100
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: PROFIBUS DP Sub-D9, Spare only.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 132H7183 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 132N0098

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132N0098

The VACON NXP Common DC Bus brake chopper unit with order code 132N0098 and type code NXB01006-G0T08SV-A1A2000000+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus Brake Chopper Unit 137L1495

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L1495

The VACON NXP Common DC Bus brake chopper unit with order code 137L1495 and type code NXB01006-A0T08SV-A1A20000E3 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137N4047

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137N4047

The VACON NXP Common DC Bus brake chopper unit with order code 137N4047 and type code NXB03256-B0T08SO-0000000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137U0907

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137U0907

The VACON NXP Common DC Bus brake chopper unit with order code 137U0907 and type code NXB04166-A0T08SG-A1A20000E9+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132X0480

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132X0480

The VACON NXP Common DC Bus brake chopper unit with order code 132X0480 and type code NXB00626-A0T08SV-A1A20000E9+DLFR+GABV is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08...