  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137N7404
  • VACON NXP Common DC Bus Brake Chopper Unit 137N7404
VACON NXP Common DC Bus Brake Chopper Unit 137N7404

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137N7404

Send inquiry Order code: 137N7404
(You save )
Brand
VACON
SKU:
137N7404
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
205
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI09
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB02055-A0T08SG-A1A200CI00+FL23+DLDE

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 137N7404 and type code NXB02055-A0T08SG-A1A200CI00+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It is rated 205 A continuous output current and meets EMC category C4.

Key specifications

Order code137N7404
Type codeNXB02055-A0T08SG-A1A200CI00+FL23+DLDE
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current205 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP00
Frame sizeFI09
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 372 mm
Net weight67 kg
EAN5715253655239

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0205205 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot DCIModbus/TCP
Option Slot E00No board
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLDEGerman
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI09Frame 09 INU
Motor Power Low Overload [kW]2X1302X130
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X372239X1030X372
Continuous Current (NO) [A]2X2052X205
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot D: Modbus/TCP.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 137N7404 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 132L9382

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132L9382

The VACON NXP Common DC Bus brake chopper unit with order code 132L9382 and type code NXB03005-A0T08SG-A1B1A5B8E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137G4662

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137G4662

The VACON NXP Common DC Bus brake chopper unit with order code 137G4662 and type code NXB03855-A0T08SG-A8A20000E3+GALR is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132X0575

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X0575

The VACON NXP Common DC Bus brake chopper unit with order code 132X0575 and type code NXB02615-G0T08SG-A1A20000CP+FL26+DLRU is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 136U3997

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136U3997

The VACON NXP Common DC Bus brake chopper unit with order code 136U3997 and type code NXB01685-A0T08SG-A1A200D6EC is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 136U2552

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136U2552

The VACON NXP Common DC Bus brake chopper unit with order code 136U2552 and type code NXB01405-A0T08SV-A1A2000000+DLFR is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08...