Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
140
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FR08
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB01405-A0T08SV-A1A2000000+DLFR

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 136U2552 and type code NXB01405-A0T08SV-A1A2000000+DLFR is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08 configuration. It is rated 140 A continuous output current and meets EMC category C4.

Key specifications

Order code136U2552
Type codeNXB01405-A0T08SV-A1A2000000+DLFR
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current140 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP00
Frame sizeFR08
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Net weight58 kg
EAN5714853005352

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0140140 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLFRFrench
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]2X892X89
Motor Power High Overload [kW]--
Continuous Current (NO) [A]2X1402X140
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136U2552 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 136X6672

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136X6672

The VACON NXP Common DC Bus brake chopper unit with order code 136X6672 and type code NXB03005-A0T08SG-A1A20000EC+LS60 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137H5016

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137H5016

The VACON NXP Common DC Bus brake chopper unit with order code 137H5016 and type code NXB01405-A0T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137U4059

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137U4059

The VACON NXP Common DC Bus brake chopper unit with order code 137U4059 and type code NXB01685-A0T08SG-A1A200CI00 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132N7908

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132N7908

The VACON NXP Common DC Bus brake chopper unit with order code 132N7908 and type code NXB04605-G0T08SG-A8A20000E3 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132X3172

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X3172

The VACON NXP Common DC Bus brake chopper unit with order code 132X3172 and type code NXB03005-A0T08SG-A8A20000E3+GACS is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...