  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 525-690 V
  • VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137N5795
  • VACON NXP Air Cooled AC Drive 137N5795
VACON NXP Air Cooled AC Drive 137N5795

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137N5795

Send inquiry Order code: 137N5795
(You save )
Brand
VACON
SKU:
137N5795
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
37.5
Rated current (A):
41
Mains voltage:
525-690 V
Enclosure:
IP21
Frame size:
FR07
EMC category:
C4
Brake chopper:
Yes
Control panel:
Alphanumeric Keypad
Type code:
NXP00416-A2T1SSV-A1AFB50000

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137N5795 and type code NXP00416-A2T1SSV-A1AFB50000 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated 41 A continuous output current, meets EMC category C4 and has an integrated brake chopper.

Key specifications

Order code137N5795
Type codeNXP00416-A2T1SSV-A1AFB50000
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power37.5 kW
Power, high overload30 kW
Rated current41 A
Current, high overload34 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR07
EMC categoryC4
Brake chopperIntegrated
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)591 x 237 x 257 mm
Net weight35 kg
EAN5715253637846

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current004141 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper1Integrated Brake chopper
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CB53RO(NO)
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR07Frame 07
Motor Power Low Overload [kW]37,537,5
Motor Power High Overload [kW]3030
Dimensions WxHxD [mm]237X591X257237X591X257
Continuous Current (NO) [A]4141
Continuous Current (HO) [A]3434
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 37.5 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 30 kW / 34 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: 3RO(NO).

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137N5795 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137L4717

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L4717

The VACON NXP Air Cooled AC Drive with order code 137L4717 and type code NXP00416-A2T0SSV-A1A2000000 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137L9826

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L9826

The VACON NXP Air Cooled AC Drive with order code 137L9826 and type code NXP00416-A2L0SSV-A1A3000000+DPAP+DLIT is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Air Cooled AC Drive 137L3837

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L3837

The VACON NXP Air Cooled AC Drive with order code 137L3837 and type code NXP00416-A2T0SSV-A1A30000E5 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137L9879

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L9879

The VACON NXP Air Cooled AC Drive with order code 137L9879 and type code NXP00416-A2L0SSV-A1A3000000+QGLM+FL23+DPAP+DLDE is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07...
VACON NXP Air Cooled AC Drive 137G3044

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137G3044

The VACON NXP Air Cooled AC Drive with order code 137G3044 and type code NXP00416-A2T1SSV-A8A3A5B200+APFIFF09 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It...