  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 525-690 V
  • VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L3837
  • VACON NXP Air Cooled AC Drive 137L3837
VACON NXP Air Cooled AC Drive 137L3837

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L3837

Send inquiry Order code: 137L3837
(You save )
Brand
VACON
SKU:
137L3837
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
37.5
Rated current (A):
41
Mains voltage:
525-690 V
Enclosure:
IP21
Frame size:
FR07
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP00416-A2T0SSV-A1A30000E5

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137L3837 and type code NXP00416-A2T0SSV-A1A30000E5 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated 41 A continuous output current and meets EMC category C4.

Key specifications

Order code137L3837
Type codeNXP00416-A2T0SSV-A1A30000E5
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power37.5 kW
Power, high overload30 kW
Rated current41 A
Current, high overload34 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR07
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)591 x 237 x 257 mm
Net weight35 kg
EAN5715253512181

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current004141 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot C00No board
Option Slot D00No board
Option Slot EE5PROFIBUS DP with Sub-D9
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR07Frame 07
Motor Power Low Overload [kW]37,537,5
Motor Power High Overload [kW]3030
Dimensions WxHxD [mm]237X591X257237X591X257
Continuous Current (NO) [A]4141
Continuous Current (HO) [A]3434

Typical applications

At 37.5 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 30 kW / 34 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 1RO(NO/NC),1RO(NC), therm; slot E: PROFIBUS DP with Sub-D9.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137L3837 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137L7054

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L7054

The VACON NXP Air Cooled AC Drive with order code 137L7054 and type code NXP00416-A2L0SSV-A1A20000E5 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N0712

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137N0712

The VACON NXP Air Cooled AC Drive with order code 137N0712 and type code NXP00416-A2T0SSV-A8A200B5E9+QGLM+APFIFF09+DPAP+DLES+GABV+LPC2+SPXE is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure,...
VACON NXP Air Cooled AC Drive 137L1032

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137L1032

The VACON NXP Air Cooled AC Drive with order code 137L1032 and type code NXP00416-A2L0SSV-A1A3B400E5+GSSE is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is...
VACON NXP Air Cooled AC Drive 132X9416

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 132X9416

The VACON NXP Air Cooled AC Drive with order code 132X9416 and type code NXP00416-A2L0SSV-A1A20000C5+DLES is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is...
VACON NXP Air Cooled AC Drive 137N7270

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137N7270

The VACON NXP Air Cooled AC Drive with order code 137N7270 and type code NXP00416-A2T0SSV-A1A20000CQ is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated...