<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137U6919

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U6919

The VACON NXP Common DC Bus active front end unit with order code 137U6919 and type code NXA04605-A0T02SG-A1A20000CP+FL28+ARFIF106+DLSK is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137U6906

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U6906

The VACON NXP Common DC Bus active front end unit with order code 137U6906 and type code NXA04605-G0T02SG-A1A2B50000+FL26+DLCN+GACS is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137U6894

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U6894

The VACON NXP Common DC Bus active front end unit with order code 137U6894 and type code NXA04605-G0T02SG-A1A2B500E9+FL26+ARFIFF05 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137U6831

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137U6831

The VACON NXP Common DC Bus active front end unit with order code 137U6831 and type code NXA10306-G0T02SG-A1A2B50000+ARFIF106 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U6689

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U6689

The VACON NXP Common DC Bus active front end unit with order code 137U6689 and type code NXA13005-A0T02SG-A1A2D7B5E2 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U6524

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137U6524

The VACON NXP Common DC Bus active front end unit with order code 137U6524 and type code NXA11505-A0T02SG-A8A2B50000+FL26+DLCN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U6509

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U6509

The VACON NXP Common DC Bus active front end unit with order code 137U6509 and type code NXA04605-A0T02SG-A1A200CI00+FL26 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U6486

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 137U6486

The VACON NXP Common DC Bus active front end unit with order code 137U6486 and type code NXA09206-A0T02SG-A1A2A5B5E9+ARFIFF30 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U6333

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U6333

The VACON NXP Common DC Bus active front end unit with order code 137U6333 and type code NXA04605-A0T02SG-A1A2B5D2EA+FL23+DLDE+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 137U6216

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U6216

The VACON NXP Common DC Bus brake chopper unit with order code 137U6216 and type code NXB00385-A2T08SV-A1000000E7 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137U6126

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137U6126

The VACON NXP Common DC Bus active front end unit with order code 137U6126 and type code NXA02615-A0T02SG-A1AFD700EC+FL23+ARFIFF05+DLDE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137U5938

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137U5938

The VACON NXP Common DC Bus active front end unit with order code 137U5938 and type code NXA03855-A0T02SG-A1A2B50000+ARFIFF05+GSNT+LPC2+SPXE is a 259 kW, three-phase 380-500 V supply, IP00 enclosure,...
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • Next