VACON NXP Common DC Bus Active Front End Unit 137U6689

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U6689

Send inquiry Order code: 137U6689
(You save )
Brand
VACON
SKU:
137U6689
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
874
Rated current (A):
1300
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI13
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA13005-A0T02SG-A1A2D7B5E2

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 137U6689 and type code NXA13005-A0T02SG-A1A2D7B5E2 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13 configuration. It is rated 1300 A continuous output current and meets EMC category C4.

Key specifications

Order code137U6689
Type codeNXA13005-A0T02SG-A1A2D7B5E2
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power874 kW
Rated current1300 A
Current, high overload1150 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI13
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 708 x 553 mm
Net weight292 kg
EAN5715253751870

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current13001300 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot DB53RO(NO)
Option Slot EE2RS485 (Modbus/N2)
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI13Frame 13 INU
Motor Power Low Overload [kW]874874
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]708X1030X553708X1030X553
Continuous Current (NO) [A]13001300
Continuous Current (HO) [A]11501150

Typical applications

At 874 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot D: 3RO(NO); slot E: RS485 (Modbus/N2).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 137U6689 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 137H1291

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137H1291

The VACON NXP Common DC Bus active front end unit with order code 137H1291 and type code NXA13005-G0T02SO-A1A2B800CP+FL26 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U0537

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U0537

The VACON NXP Common DC Bus active front end unit with order code 137U0537 and type code NXA13005-A0T02SG-A1A2B500E2 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 132L8822

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132L8822

The VACON NXP Common DC Bus active front end unit with order code 132L8822 and type code NXA13005-A0T02SG-A1A2D7D2E9+FL24+GRID+ARFIF106+DLCZ is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 136H4755

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136H4755

The VACON NXP Common DC Bus active front end unit with order code 136H4755 and type code NXA13005-A0T02SG-A1A20000CI is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136H3940

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136H3940

The VACON NXP Common DC Bus active front end unit with order code 136H3940 and type code NXA13005-G0T02SG-A1A2000000+FL26+DLCN is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...