  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137U6126
  • VACON NXP Common DC Bus Active Front End Unit 137U6126
VACON NXP Common DC Bus Active Front End Unit 137U6126

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137U6126

Send inquiry Order code: 137U6126
(You save )
Brand
VACON
SKU:
137U6126
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
175
Rated current (A):
261
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI09
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA02615-A0T02SG-A1AFD700EC+FL23+ARFIFF05+DLDE

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 137U6126 and type code NXA02615-A0T02SG-A1AFD700EC+FL23+ARFIFF05+DLDE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It is rated 261 A continuous output current and meets EMC category C4.

Key specifications

Order code137U6126
Type codeNXA02615-A0T02SG-A1AFD700EC+FL23+ARFIFF05+DLDE
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power175 kW
Rated current261 A
Current, high overload205 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI09
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 372 mm
Net weight67 kg
EAN5715253745886

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0261261 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot EECEtherCAT
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLDEGerman
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF05AFE II application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI09Frame 09 INU
Motor Power Low Overload [kW]175175
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X372239X1030X372
Continuous Current (NO) [A]261261
Continuous Current (HO) [A]205205
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 175 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: Line voltage meas.; slot E: EtherCAT.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 137U6126 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 137N7681

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N7681

The VACON NXP Common DC Bus active front end unit with order code 137N7681 and type code NXA02615-A0T02SG-A1A2D7B500+GSNT+DLFR+SPXE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G4462

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137G4462

The VACON NXP Common DC Bus active front end unit with order code 137G4462 and type code NXA02615-A0T02SG-A1A2B50000+FL23+ARFIF106+DLDE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137L7264

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L7264

The VACON NXP Common DC Bus active front end unit with order code 137L7264 and type code NXA02615-A0T02SG-A1A2B50000+ARFIFF05+GAAB is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136X7432

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 136X7432

The VACON NXP Common DC Bus active front end unit with order code 136X7432 and type code NXA02615-A0T02SG-A1A20000CI+ARFIFF05 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137N7113

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N7113

The VACON NXP Common DC Bus active front end unit with order code 137N7113 and type code NXA02615-A0T02SG-A1A2000000+ARFIFF05+LPC2 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...