  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0735

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 343 kW 525-690V IP00 - 137X0735

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0735 and type code NXA03256-A0T02WG-A1A300D6E3+FL23+MASG+ARFIFF03+DLDE is a 343 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0955

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 319 kW 380-500V IP00 - 137X0955

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0955 and type code NXA05205-A0T02WG-A8B5B1B8E9+GSNT+GALR+SPXE is a 319 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137X2197

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 542 kW 525-690V IP00 - 137X2197

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137X2197 and type code NXB03256-A0T08WG-A1A200E2E3 is a 542 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X1311

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 137X1311

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X1311 and type code NXA08205-A0T02WG-A1B1BH00E9+EMAR is a 502 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X2230

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1796 kW 525-690V IP00 - 137X2230

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X2230 and type code NXA17006-A0T02WG-A8B1D7D2E3 is a 1796 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137X1371

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 838 kW 525-690V IP00 - 137X1371

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137X1371 and type code NXB05028-A0T08WG-A1A20000E9+GSNT+EMAR+LPC2+SPXE is a 838 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0699

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 623 kW 525-690V IP00 - 137X0699

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0699 and type code NXA05906-A0T02WG-A1AFD7B1E9+MASG+ARFIFF03 is a 623 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0697

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 137X0697

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0697 and type code NXA10306-A0T02WG-A1AF00B1E9 is a 1088 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137X0591

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 435 kW 525-690V IP00 - 137X0591

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137X0591 and type code NXB02618-A0T08WG-ANB1000000+GSNT+GACS+SPXE is a 435 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0409

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137X0409

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0409 and type code NXA15006-G0T02WG-A8B1B5B1E9+FL26+DLCN is a 1586 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0353

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137X0353

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0353 and type code NXA15006-A0T02WG-ANB1D7B1E5+MASG+ARFIFF03+GSNT+GAAB+SPXE is a 1586 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137X0352

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 838 kW 525-690V IP00 - 137X0352

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137X0352 and type code NXB05026-A0T08WG-A8A2000000+GSNT+GAAB+SPXE is a 838 kW, three-phase 525-690 V supply,...
  • Previous
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • Next