<
<
  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137X0409
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0409
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0409

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137X0409

Send inquiry Order code: 137X0409
(You save )
Brand
VACON
SKU:
137X0409
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1586
Rated current (A):
1500
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA15006-G0T02WG-A8B1B5B1E9+FL26+DLCN

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0409 and type code NXA15006-G0T02WG-A8B1B5B1E9+FL26+DLCN is a 1586 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH64 configuration. It is rated 1500 A continuous output current and meets EMC category C4.

Key specifications

Order code137X0409
Type codeNXA15006-G0T02WG-A8B1B5B1E9+FL26+DLCN
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1586 kW
Rated current1500 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5715253790275

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current15001500 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BB16 programmableDI/DO
Option Slot CB53RO(NO)
Option Slot DB16 programmableDI/DO
Option Slot EE92-port ethernet
Firmware language package+FL26UK,RU,CN;Others
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLCNChinese
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]15861586
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]13641364
Continuous Current (HO) [A]--

Typical applications

At 1586 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 6 programmableDI/DO; slot C: 3RO(NO); slot D: 6 programmableDI/DO; slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137X0409 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X0353

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137X0353

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X0353 and type code NXA15006-A0T02WG-ANB1D7B1E5+MASG+ARFIFF03+GSNT+GAAB+SPXE is a 1586 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N9487

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137N9487

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N9487 and type code NXA15006-G0T02WG-A8A2000000+GADN is a 1586 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137X2233

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137X2233

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137X2233 and type code NXA15006-G0T02WG-ANB1B8B8E9+FL26+DLCN+GACS is a 1586 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L4308

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 132L4308

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L4308 and type code NXA15006-A0T02WG-A1A2D700E9+MASG+ARFIFF03+GALR is a 1586 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L8648

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137L8648

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L8648 and type code NXA15006-A0T02WG-A8A20000E2+FL21+ARFIFF05+GSNT+GALR+LPC2+SPXE is a 1586 kW,...