  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B5E9E5 132H4106 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H4106 and type code NXA04605-A0T02SG-A1A2B5E9E5+FL23+ARFIFF05+DLDE+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2B50000 132H3939 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3939 and type code NXA03855-A0T02SG-A1A2B50000+FL23+GSNT+GALR+SPXE is a 259 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0SSV-0000000000 132H3925 – VACON NXP Common DC Bus Rectifier Unit, 410 kW, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132H3925 and type code NXN06506-X0T0SSV-0000000000+SPXE is a 410 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A8A2B5D2E9 132H3878 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3878 and type code NXA04605-A0T02SG-A8A2B5D2E9+FL25+LS60 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B50000 132H3872 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3872 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+GALR+SPXV is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A2B50000 132H3870 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3870 and type code NXA10306-A0T02SG-A1A2B50000+GSNT+GAKR+SPXV is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01256-A0T02SG-A1A2D700EA 132H3683 – VACON NXP Common DC Bus Active Front End Unit, 145 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3683 and type code NXA01256-A0T02SG-A1A2D700EA+UGRD+ARFIF106+LS60 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2B50000 132H3718 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3718 and type code NXA13005-A0T02SG-A1A2B50000+GSNT+DLFR+SPXC is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-G0T08SG-A1B50000CP 132H3085 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132H3085 and type code NXB04166-G0T08SG-A1B50000CP+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B50000 132H3537 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H3537 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+DLDE+SPXC is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0SSV-0000000000 132H2988 – VACON NXP Common DC Bus Rectifier Unit, 410 kW, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132H2988 and type code NXN06506-X0T0SSV-0000000000+GACS is a 410 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB01055-A2T08SV-A1B100B8E9 132H2906 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132H2906 and type code NXB01055-A2T08SV-A1B100B8E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...