  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132H3718
  • VACON NXP Common DC Bus Active Front End Unit 132H3718
VACON NXP Common DC Bus Active Front End Unit 132H3718

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132H3718

Send inquiry Order code: 132H3718
(You save )
Brand
VACON
SKU:
132H3718
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
874
Rated current (A):
1300
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI13
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA13005-A0T02SG-A1A2B50000+GSNT+DLFR+SPXC

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 132H3718 and type code NXA13005-A0T02SG-A1A2B50000+GSNT+DLFR+SPXC is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13 configuration. It is rated 1300 A continuous output current and meets EMC category C4.

Key specifications

Order code132H3718
Type codeNXA13005-A0T02SG-A1A2B50000+GSNT+DLFR+SPXC
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power874 kW
Power, high overload772 kW
Rated current1300 A
Current, high overload1355 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI13
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 708 x 553 mm
Net weight306 kg
EAN5714853326853

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current13001300 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CB53RO(NO)
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLFRFrench
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI13Frame 13 INU
Motor Power Low Overload [kW]874874
Motor Power High Overload [kW]772772
Dimensions WxHxD [mm]708X1030X553708X1030X553
Continuous Current (NO) [A]15331533
Continuous Current (HO) [A]13551355

Typical applications

At 874 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • For heavy-duty use with high overload the rating is 772 kW / 1355 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 3RO(NO).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 132H3718 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 137U4804

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U4804

The VACON NXP Common DC Bus active front end unit with order code 137U4804 and type code NXA13005-A0T02SG-A1A20000E5 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136X6667

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136X6667

The VACON NXP Common DC Bus active front end unit with order code 136X6667 and type code NXA13005-A0T02SG-A1A2D7B5EC+GRDC+ARFIF106+LS60 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H5776

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137H5776

The VACON NXP Common DC Bus active front end unit with order code 137H5776 and type code NXA13005-A0T02SG-A1A20000EC+FL26+ARFIFF05+DLCN is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137G9558

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137G9558

The VACON NXP Common DC Bus active front end unit with order code 137G9558 and type code NXA13005-A0T02SG-A1A2000000+ARFIFF05 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U4307

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U4307

The VACON NXP Common DC Bus active front end unit with order code 137U4307 and type code NXA13005-G0T02SG-A8A2B50000 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...