  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB00875-A2T08SV-A1A2000000 136G0138 – VACON NXP Common DC Bus Brake Chopper Unit, 45 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 136G0138 and type code NXB00875-A2T08SV-A1A2000000 is a 45 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration...
VACON NXP Common DC Bus Brake Chopper Unit 136F9790

VACON 

NXB00225-A2T08SV-A100000000 136F9790 – VACON NXP Common DC Bus Brake Chopper Unit, 11 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 136F9790 and type code NXB00225-A2T08SV-A100000000 is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB01055-A2T08SV-A9A20000CQ 136F8127 – VACON NXP Common DC Bus Brake Chopper Unit, 55 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 136F8127 and type code NXB01055-A2T08SV-A9A20000CQ+DLCN is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB02616-G0T08SG-A1A20000CP 132X9551 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132X9551 and type code NXB02616-G0T08SG-A1A20000CP+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04605-A0T08SG-A8A20000E9 132X9950 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132X9950 and type code NXB04605-A0T08SG-A8A20000E9+GACS is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A8A20000E9 132X9965 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X9965 and type code NXA01685-G0T02SG-A8A20000E9+GSNT+SPXE is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB01055-A2T08SV-A9A20000CQ 136F8126 – VACON NXP Common DC Bus Brake Chopper Unit, 55 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 136F8126 and type code NXB01055-A2T08SV-A9A20000CQ is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2B50000 132X9825 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X9825 and type code NXA13005-A0T02SG-A1A2B50000+ARFIFF05 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B50000 132X9546 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X9546 and type code NXA04605-A0T02SG-A1A2B50000+FL26+DLCN+GACS is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2D7E900 132X9954 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X9954 and type code NXA02615-A0T02SG-A1A2D7E900 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2D7B5E9 132X9921 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X9921 and type code NXA03855-A0T02SG-A1A2D7B5E9 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2B50000 132X9578 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X9578 and type code NXA03256-A0T02SG-A1A2B50000+FL23+DLDE is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • Next