  • Search

VACON NXP

  • Home
  • Drives
  • VACON NXP

VACON NXP

VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-0000000000 137U1146 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U1146 and type code NXB04166-A0T08SG-0000000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A1A3B1B5E9 137U0856 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0856 and type code NXA01685-G0T02SG-A1A3B1B5E9+ARFIFF05+DNOT is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-G0T02SG-A8B1D7D2E9 137U1082 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U1082 and type code NXA03855-G0T02SG-A8B1D7D2E9+ARFIFF03 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-A1A2000000 137U0806 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U0806 and type code NXB04166-A0T08SG-A1A2000000+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-A1A20000E9 137U0907 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U0907 and type code NXB04166-A0T08SG-A1A20000E9+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2B500E2 137U0537 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0537 and type code NXA13005-A0T02SG-A1A2B500E2 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A1A20000EA 137U0609 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0609 and type code NXA01685-G0T02SG-A1A20000EA is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB00725-G2T08SV-A1A2000000 137U0596 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137U0596 and type code NXB00725-G2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B500E2 137U0535 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0535 and type code NXA04605-A0T02SG-A1A2B500E2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A1A2D700E9 137U0707 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0707 and type code NXA02055-A0T02SG-A1A2D700E9+GRDC+ARFIF106 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FR08, IP21

VACON 

NXB01405-B2T08SV-A8A20000E9 137U0668 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137U0668 and type code NXB01405-B2T08SV-A8A20000E9+SPXE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-B0T02SG-A8A2B500E9 137U0665 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0665 and type code NXA04605-B0T02SG-A8A2B500E9+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • Next