  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 137U6944
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U6944
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U6944

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 137U6944

Send inquiry Order code: 137U6944
(You save )
Brand
VACON
SKU:
137U6944
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
793
Rated current (A):
750
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA07506-G0T02WG-ANB1D7E300+MASG+ARFIFF03+GSNT+GACS+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U6944 and type code NXA07506-G0T02WG-ANB1D7E300+MASG+ARFIFF03+GSNT+GACS+SPXE is a 793 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH63 configuration. It is rated 750 A continuous output current and meets EMC category C4.

Key specifications

Order code137U6944
Type codeNXA07506-G0T02WG-ANB1D7E300+MASG+ARFIFF03+GSNT+GACS+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power793 kW
Rated current750 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/O6DI,2AI,2AO,10/-10Vref,24V
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5715253754420

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0750750 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AAN6DI,2AI,2AO,10/-10Vref,24V
Option Slot BB16 programmableDI/DO
Option Slot CD7Line voltage meas.
Option Slot DE3PROFIBUS DP
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software license+MASGGrid Converter license
Application+ARFIFF03Grid Converter NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GACSChina Classification Society
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]793793
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]682682
Continuous Current (HO) [A]--

Typical applications

At 793 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,2AI,2AO,10/-10Vref,24V; slot B: 6 programmableDI/DO; slot C: Line voltage meas.; slot D: PROFIBUS DP.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137U6944 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L5040

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 132L5040

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L5040 and type code NXA07506-A0T02WO-A1A3000000+FL23+DLDE is a 793 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L7533

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 132L7533

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L7533 and type code NXA07506-A0T02WG-A1A2D7E900+FNP02V200+GRID+ARFIF106V103+L0023+LS60+GSSE+GAUG is a...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X5413

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 132X5413

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X5413 and type code NXA07506-A0T02WG-A1A2D700E9+MASG+ARFIFF03 is a 793 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H6888

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 137H6888

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H6888 and type code NXA07506-G0T02WG-A8A3A50000+FL26+DLCN is a 793 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H4302

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 137H4302

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H4302 and type code NXA07506-A0T02PG-A1B1D7B1E9+MASG+ARFIFF03 is a 793 kW, three-phase 525-690 V...