  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 137U2168
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U2168
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U2168

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 137U2168

Send inquiry Order code: 137U2168
(You save )
Brand
VACON
SKU:
137U2168
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
687
Rated current (A):
650
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Type code:
NXA06506-B0T02PG-A1A2D700EA+FL23+ARFIFF05+DNOT+GNUL+GNKC+GNUA+GNEA+LPC2+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U2168 and type code NXA06506-B0T02PG-A1A2D700EA+FL23+ARFIFF05+DNOT+GNUL+GNKC+GNUA+GNEA+LPC2+SPXE is a 687 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH63 configuration. It is rated 650 A continuous output current and meets EMC category C4.

Key specifications

Order code137U2168
Type codeNXA06506-B0T02PG-A1A2D700EA+FL23+ARFIFF05+DNOT+GNUL+GNKC+GNUA+GNEA+LPC2+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power687 kW
Rated current650 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5715253705163

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationPLiquidCooled w. nickel element
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0650650 Amp
Control KeypadBNo local control panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot EEAAdvanced 2-port ethernet
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DNOTNo manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF05AFE II application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GNULNo UL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GNKCNo Korean Approval
Ukrainian Approval+GNUANo Ukrainian Approval
EAC Approval+GNEANo EAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]687687
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]591591
Continuous Current (HO) [A]--

Typical applications

At 687 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot E: Advanced 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137U2168 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N8180

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 132N8180

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N8180 and type code NXA06506-A0T02WG-A1A2B50000+FL23+ARFIFF05+GALR+LPC2+SPXE is a 687 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N0409

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 132N0409

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N0409 and type code NXA06506-A0T02WG-A8B1D7D6E9+MASG+ARFIFF03+GALR+LPC2+SPXE is a 687 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U2169

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 137U2169

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U2169 and type code NXA06506-A0T02WG-A1A2D700EA+FL23+ARFIFF05+DNOT+DLDE+GNUL+GNKC+GNUA+LPC2+SPXE is a...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U5060

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 137U5060

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U5060 and type code NXA06506-A0T02WG-A8A2D7B1EA+FL23+ARFIFF05+GSNT+DLDE+GNUL+GNKC+GNUA+LPC2+SPXE is a...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U7912

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 137U7912

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U7912 and type code NXA06506-A0T02WG-A8B100CQE6 is a 687 kW, three-phase 525-690 V supply, IP00...