Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
686
Rated current (A):
590
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA05906-A0T02WG-A1A300D6E9+GADN

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N2235 and type code NXA05906-A0T02WG-A1A300D6E9+GADN is a 686 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH63 configuration. It is rated 590 A continuous output current and meets EMC category C4.

Key specifications

Order code136N2235
Type codeNXA05906-A0T02WG-A1A300D6E9+GADN
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power686 kW
Rated current590 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5710108899622

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0590590 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot C00No board
Option Slot DD6CAN-MonBus galv.decoupled
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GADNNorskeVeritas&GermanischeLloyd
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]686686
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]699699
Continuous Current (HO) [A]--

Typical applications

At 686 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 1RO(NO/NC),1RO(NC), therm; slot D: CAN-MonBus galv.decoupled; slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 136N2235 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H0398

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 686 kW 525-690V IP00 - 132H0398

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H0398 and type code NXA05906-A0T02WG-A1A20000CI is a 686 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136H1071

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 686 kW 525-690V IP00 - 136H1071

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136H1071 and type code NXA05906-A0T02WG-A1A2000000 is a 686 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H3947

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 686 kW 525-690V IP00 - 132H3947

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H3947 and type code NXA05906-A0T02WG-A8B500D6CI+GSNT+SPXE is a 686 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136H5081

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 686 kW 525-690V IP00 - 136H5081

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136H5081 and type code NXA05906-A0T02WG-A1A300D6E9+FL23+DLDE+GADN is a 686 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N2237

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 686 kW 525-690V IP00 - 136N2237

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N2237 and type code NXA05906-A0T02WG-A1A2D7D6E9+GADN is a 686 kW, three-phase 525-690 V supply, IP00...