  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 132H3945
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H3945
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H3945

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 132H3945

Send inquiry Order code: 132H3945
(You save )
Brand
VACON
SKU:
132H3945
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
584
Rated current (A):
502
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH62
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA05026-A0T02WG-A8B500D6CI+GSNT+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H3945 and type code NXA05026-A0T02WG-A8B500D6CI+GSNT+SPXE is a 584 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH62 configuration. It is rated 502 A continuous output current and meets EMC category C4.

Key specifications

Order code132H3945
Type codeNXA05026-A0T02WG-A8B500D6CI+GSNT+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power584 kW
Rated current502 A
Current, high overload335 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH62
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5714853329533

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0502502 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BB53RO(NO)
Option Slot C00No board
Option Slot DD6CAN-MonBus galv.decoupled
Option Slot ECIModbus/TCP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH62Frame 62 liquid cooled
Motor Power Low Overload [kW]584584
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]540540
Continuous Current (HO) [A]335335

Typical applications

At 584 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 3RO(NO); slot D: CAN-MonBus galv.decoupled; slot E: Modbus/TCP.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 132H3945 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1394

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 132H1394

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1394 and type code NXA05026-A0T02WG-A8B500D6CI is a 584 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136H3652

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 136H3652

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136H3652 and type code NXA05026-A0T02PG-A1A2B20000 is a 584 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H0401

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 132H0401

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H0401 and type code NXA05026-A0T02WG-A1A20000CI is a 584 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136X6334

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 136X6334

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136X6334 and type code NXA05026-A0T02WG-A1A20000E9+LS60 is a 584 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H4889

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132H4889

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H4889 and type code NXA11806-A0T02WG-A1B1D7D2E9+FL23+ARFIFF03+DLDE+GALR+LPC2 is a 1247 kW, three-phase...