<
<
  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 380-500 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 132X6533
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X6533
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X6533

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 132X6533

Send inquiry Order code: 132X6533
(You save )
Brand
VACON
SKU:
132X6533
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
563
Rated current (A):
920
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA09205-A0T02WG-0000000000+ARFIFF05+GSNT+GAKR+LPC2+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X6533 and type code NXA09205-A0T02WG-0000000000+ARFIFF05+GSNT+GAKR+LPC2+SPXE is a 563 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63 configuration. It is rated 920 A continuous output current and meets EMC category C4.

Key specifications

Order code132X6533
Type codeNXA09205-A0T02WG-0000000000+ARFIFF05+GSNT+GAKR+LPC2+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power563 kW
Rated current920 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/ONo board
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5715253215525

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0920920 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot A00No board
Option Slot B00No board
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF05AFE II application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GAKRKorea Register of Shipping
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]563563
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]836836
Continuous Current (HO) [A]--

Typical applications

At 563 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 132X6533 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H7299

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 137H7299

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H7299 and type code NXA09205-G0T02WG-A1A2D700E9+FL26+ARFIFF02V141+DLCN is a 563 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N1464

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 132N1464

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N1464 and type code NXA09205-A0T02WG-A8AFD7BHE9 is a 563 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N1465

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 132N1465

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N1465 and type code NXA09205-A0T02WG-A8AFBHBHE9 is a 563 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N7818

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 132N7818

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N7818 and type code NXA09205-A0T02WG-A8AFD70000 is a 563 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N7816

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 132N7816

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N7816 and type code NXA09205-A0T02WG-A8AF000000 is a 563 kW, three-phase 380-500 V supply, IP00...