  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 380-500 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 132N8752
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N8752
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N8752

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 132N8752

Send inquiry Order code: 132N8752
(You save )
Brand
VACON
SKU:
132N8752
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
502
Rated current (A):
820
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA08205-A0T02WG-A8A2BHBH00+ARFIFF03+LPC2+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N8752 and type code NXA08205-A0T02WG-A8A2BHBH00+ARFIFF03+LPC2+SPXE is a 502 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63 configuration. It is rated 820 A continuous output current and meets EMC category C4.

Key specifications

Order code132N8752
Type codeNXA08205-A0T02WG-A8A2BHBH00+ARFIFF03+LPC2+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power502 kW
Rated current820 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5715253130484

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0820820 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA22RO(NO/NC)
Option Slot CBH3 temp meas channels
Option Slot DBH3 temp meas channels
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF03Grid Converter NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]502502
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]745745
Continuous Current (HO) [A]--

Typical applications

At 502 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 2RO(NO/NC); slot C: 3 temp meas channels; slot D: 3 temp meas channels.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 132N8752 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L9955

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 137L9955

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L9955 and type code NXA08205-A0T02WG-A1A2D7BHE9+MASG+ARFIFF03+GALR is a 502 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N5975

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 137N5975

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N5975 and type code NXA08205-A0T02WG-A1A2B50000 is a 502 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X2704

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 132X2704

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X2704 and type code NXA08205-A0T02WG-0000000000+ARFIFF05+GSNT+GAKR+LPC2+SPXE is a 502 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N6695

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 132N6695

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N6695 and type code NXA08205-A0T02WG-A1A2B5D2EC+FL21+ARFIFF05+DLDE+LPC2+SPXE is a 502 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N5203

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 132N5203

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N5203 and type code NXA08205-A0T02WG-A1A2B5D2EC+FL23+ARFIFF05+DLDE+LPC2 is a 502 kW, three-phase...