  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 484 kW 525-690V IP00 - 136N2234
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N2234
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N2234

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 484 kW 525-690V IP00 - 136N2234

Send inquiry Order code: 136N2234
(You save )
Brand
VACON
SKU:
136N2234
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
484
Rated current (A):
416
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH62
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA04166-A0T02WG-A1A3D7D6E9+GADN

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N2234 and type code NXA04166-A0T02WG-A1A3D7D6E9+GADN is a 484 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH62 configuration. It is rated 416 A continuous output current and meets EMC category C4.

Key specifications

Order code136N2234
Type codeNXA04166-A0T02WG-A1A3D7D6E9+GADN
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power484 kW
Rated current416 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH62
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5710108899752

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0416416 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot CD7Line voltage meas.
Option Slot DD6CAN-MonBus galv.decoupled
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GADNNorskeVeritas&GermanischeLloyd
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH62Frame 62 liquid cooled
Motor Power Low Overload [kW]484484
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]493493
Continuous Current (HO) [A]--

Typical applications

At 484 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 1RO(NO/NC),1RO(NC), therm; slot C: Line voltage meas.; slot D: CAN-MonBus galv.decoupled; slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 136N2234 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136Z4422

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 484 kW 525-690V IP00 - 136Z4422

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136Z4422 and type code NXA04166-A0T02WG-A1A2000000 is a 484 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9466

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 136L9466

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9466 and type code NXA06506-A0T02WG-A1A2B50000+FL23+GALR is a 687 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137G5726

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 137G5726

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137G5726 and type code NXA10306-A0T02WG-A1A2D7E9E9+MASG+ARFIFF03+DLES is a 1088 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136Z9909

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 866 kW 525-690V IP00 - 136Z9909

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136Z9909 and type code NXA08206-A0T02WG-A1AF0000E6+FL23+GRID+ARFIF106+DLDE is a 866 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136X2485

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 793 kW 525-690V IP00 - 136X2485

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136X2485 and type code NXA07506-A0T02WG-A1A2B5B4CI is a 793 kW, three-phase 525-690 V supply, IP00...