VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 137U8599
- Brand
- VACON
- SKU:
- 137U8599
- Condition:
- New
- Series:
- VACON NXP Liquid Cooled Common DC Bus
- Power (kW):
- 407
- Rated current (A):
- 385
- Mains voltage:
- 525-690 V
- Enclosure:
- IP00
- Frame size:
- CH62
- EMC category:
- C4
- Brake chopper:
- No
- Control panel:
- Alphanumeric Keypad
- Type code:
- NXA03856-A0T02WG-A8A2BCBHE9+ARFIFF30+GABV
Description
The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U8599 and type code NXA03856-A0T02WG-A8A2BCBHE9+ARFIFF30+GABV is a 407 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH62 configuration. It is rated 385 A continuous output current and meets EMC category C4.
Key specifications
| Order code | 137U8599 |
|---|---|
| Type code | NXA03856-A0T02WG-A8A2BCBHE9+ARFIFF30+GABV |
| Series | VACON® NXP Liquid Cooled Common DC Bus |
| Product type | Liquid-Cooled Active Front End Unit |
| Rated power | 407 kW |
| Rated current | 385 A |
| Mains voltage | 525 – 690 Vac (640-1100 Vdc) |
| Phases | Three phase |
| Enclosure | IP00 |
| Frame size | CH62 |
| EMC category | C4 |
| Brake chopper | Not included |
| Control panel | Alphanumeric Keypad |
| Standard I/O | OPTA1 w.galv.isol 2AI&1AO |
| Dimensions (H x W x D) | 658 x 246 x 374 mm |
| Net weight | 55 kg |
| EAN | 5715253771175 |
Type code configuration
| Option | Code | Selection |
|---|---|---|
| Product Group | NXA | Active Front-End Unit |
| Customized Drive | +BM26 | Vacon Dark Grey NXP |
| Mechanical Modification | W | Liquid cooling |
| Mains voltage | 6- | 525 – 690 Vac (640-1100 Vdc) |
| Current | 0385 | 385 Amp |
| Control Keypad | A | Alpha-numeric display |
| Enclosure | 0 | IP00 |
| EMC emission levels | T | IEC61800-3 for IT networks |
| Brake Chopper | 0 | No Brake |
| Electrical Modification | 2 | AFE module w/o LCL |
| Card Modifications | G- | FiberConnection+Varnished PCB |
| Shipping Package | +GSCB | Cardboard box as Shipping pack |
| Warranty | +WT01 | Warranty 12/18 months |
| Gland Plate Option | +QGNO | No conduit plate |
| Option Slot A | A8 | OPTA1 w.galv.isol 2AI&1AO |
| Option Slot B | A2 | 2RO(NO/NC) |
| Option Slot C | BC | Resolver 3xDO wide range |
| Option Slot D | BH | 3 temp meas channels |
| Option Slot E | E9 | 2-port ethernet |
| Firmware language package | +FL22 | UK,FR,IT,ES,PT;WestEur |
| Documentation Level | +DPAP | Paper manuals |
| Documentation Lang. Preference | +DLUK | English |
| System Firmware | +FNP02 | System software NXP |
| Software license | NONE | no software license |
| Application | +ARFIFF30 | Generator appl NXA,NXI,NXP |
| Parameter Set | NONE | none |
| Motor Parameter Default | +LS50 | Default Motor frequency 50HZ |
| Labeling options | +LPC1 | no additional labels |
| CE Approval | +GACE | CE Approval |
| UL Approval | +GAUL | UL approval |
| RCM Approval | +GACT | RCM Approval N16307 |
| Marine approval | +GABV | Bureau Veritas |
| KC Approval | +GAKC | Korean Approval |
| Ukrainian Approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Frame Size | CH62 | Frame 62 liquid cooled |
| Motor Power Low Overload [kW] | 407 | 407 |
| Motor Power High Overload [kW] | - | - |
| Dimensions WxHxD [mm] | 246X658X374 | 246X658X374 |
| Continuous Current (NO) [A] | 350 | 350 |
| Continuous Current (HO) [A] | - | - |
Typical applications
At 407 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.
Configuration notes
- An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
- IP00 is an open module for mounting inside a cabinet or switchgear.
- EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
- It is supplied with an alphanumeric keypad for local control and parameter setting.
- Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 2RO(NO/NC); slot C: Resolver 3xDO wide range; slot D: 3 temp meas channels; slot E: 2-port ethernet.
About the VACON NXP Liquid Cooled Common DC Bus series
VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.
Need this exact configuration or an alternative? Send us the order code 137U8599 or the type code and we will help you find the right drive.