<
<
  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 137H6886
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H6886
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H6886

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 137H6886

Send inquiry Order code: 137H6886
(You save )
Brand
VACON
SKU:
137H6886
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
407
Rated current (A):
385
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH62
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA03856-G0T02WG-A8A3D70000+FL26+GRID+ARFIF106+DLCN

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H6886 and type code NXA03856-G0T02WG-A8A3D70000+FL26+GRID+ARFIF106+DLCN is a 407 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH62 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code137H6886
Type codeNXA03856-G0T02WG-A8A3D70000+FL26+GRID+ARFIF106+DLCN
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power407 kW
Rated current385 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH62
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5715253437675

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0385385 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL26UK,RU,CN;Others
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLCNChinese
System Firmware+FNP02System software NXP
Software license+GRID+UGRD & +GRDC
Application+ARFIF106Grid Conv with codes NXA,NXI
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH62Frame 62 liquid cooled
Motor Power Low Overload [kW]407407
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]350350
Continuous Current (HO) [A]--

Typical applications

At 407 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 1RO(NO/NC),1RO(NC), therm; slot C: Line voltage meas..

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137H6886 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L5687

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 137L5687

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L5687 and type code NXA03856-A0T02WG-A1A2000000+GADN is a 407 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U4888

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 137U4888

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U4888 and type code NXA03856-A0T02WG-A8B100CQE6 is a 407 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L9584

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 132L9584

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L9584 and type code NXA03856-A0T02WG-A8A2B5D6CI+GSNT+LPC2+SPXV is a 407 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L9954

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 132L9954

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L9954 and type code NXA03856-A0T02WG-A8A2B5D6CI+GSNT+LPC2+SPXE is a 407 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X9185

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 407 kW 525-690V IP00 - 132X9185

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X9185 and type code NXA03856-A0T02WG-A1A2B5D2EC is a 407 kW, three-phase 525-690 V supply, IP00...