VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N9897

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 276 kW 525-690V IP00 - 132N9897

Send inquiry Order code: 132N9897
(You save )
Brand
VACON
SKU:
132N9897
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
276
Rated current (A):
261
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH61
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA02618-A0T02WG-0000D70000+ARFIFF05+GSNT+GABV+LPC2+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N9897 and type code NXA02618-A0T02WG-0000D70000+ARFIFF05+GSNT+GABV+LPC2+SPXE is a 276 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61 configuration. It is rated 261 A continuous output current and meets EMC category C4.

Key specifications

Order code132N9897
Type codeNXA02618-A0T02WG-0000D70000+ARFIFF05+GSNT+GABV+LPC2+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power276 kW
Rated current261 A
Mains voltage525 – 690 Vac (640-1200 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH61
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/ONo board
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5715253145921

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage8-525 – 690 Vac (640-1200 Vdc)
Current0261261 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot A00No board
Option Slot B00No board
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF05AFE II application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GABVBureau Veritas
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH61Frame 61 liquid cooled
Motor Power Low Overload [kW]276276
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]237237
Continuous Current (HO) [A]--

Typical applications

At 276 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot C: Line voltage meas..

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 132N9897 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N9326

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 276 kW 525-690V IP00 - 132N9326

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N9326 and type code NXA02616-A0T02WG-A1A20000E9+ARFIFF05+GALR is a 276 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X2163

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 276 kW 525-690V IP00 - 132X2163

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X2163 and type code NXA02616-A0T02WG-A1A2D700E9+MASG+ARFIFF03 is a 276 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137G0649

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 276 kW 525-690V IP00 - 137G0649

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137G0649 and type code NXA02616-A0T02WG-A1AFD7B1E9+MASG+ARFIFF03 is a 276 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L6689

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 276 kW 525-690V IP00 - 137L6689

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L6689 and type code NXA02618-A0T02WG-A8A2D700EA+MASG+ARFIFF03 is a 276 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136U4036

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 276 kW 525-690V IP00 - 136U4036

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136U4036 and type code NXA02616-A0T02WG-A1A3D7D6E9 is a 276 kW, three-phase 525-690 V supply, IP00...