VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136Z4419

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 242 kW 525-690V IP00 - 136Z4419

Send inquiry Order code: 136Z4419
(You save )
Brand
VACON
SKU:
136Z4419
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
242
Rated current (A):
208
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH61
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA02086-A0T02WG-A1A2000000

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136Z4419 and type code NXA02086-A0T02WG-A1A2000000 is a 242 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61 configuration. It is rated 208 A continuous output current and meets EMC category C4.

Key specifications

Order code136Z4419
Type codeNXA02086-A0T02WG-A1A2000000
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power242 kW
Rated current208 A
Current, high overload139 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH61
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5714853234202

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0208208 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH61Frame 61 liquid cooled
Motor Power Low Overload [kW]242242
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]221221
Continuous Current (HO) [A]139139

Typical applications

At 242 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 136Z4419 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H4889

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132H4889

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H4889 and type code NXA11806-A0T02WG-A1B1D7D2E9+FL23+ARFIFF03+DLDE+GALR+LPC2 is a 1247 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1394

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 132H1394

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1394 and type code NXA05026-A0T02WG-A8B500D6CI is a 584 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H0438

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 378 kW 525-690V IP00 - 132H0438

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H0438 and type code NXA03256-A0T02WG-A1A2D700CI+MASG+ARFIFF03 is a 378 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X8734

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 972 kW 525-690V IP00 - 132X8734

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X8734 and type code NXA09206-A0T02WG-A1A2B5D2EC+FL23+ARFIFF05+DNOT+DLDE+LPC2 is a 972 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H9354

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 132H9354

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H9354 and type code NXA10306-A0T02PG-ANB1D7D2E9+FL23+ARFIFF03+DLDE+GALR+LPC2 is a 1088 kW, three-phase...