  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 380-500 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 137N5756
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N5756
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N5756

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 137N5756

Send inquiry Order code: 137N5756
(You save )
Brand
VACON
SKU:
137N5756
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
236
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH61
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA03855-G0T02WG-A8A3BC00E9

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N5756 and type code NXA03855-G0T02WG-A8A3BC00E9 is a 236 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH61 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code137N5756
Type codeNXA03855-G0T02WG-A8A3BC00E9
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power236 kW
Rated current385 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH61
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5715253637457

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot CBCResolver 3xDO wide range
Option Slot D00No board
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH61Frame 61 liquid cooled
Motor Power Low Overload [kW]236236
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]350350
Continuous Current (HO) [A]--

Typical applications

At 236 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 1RO(NO/NC),1RO(NC), therm; slot C: Resolver 3xDO wide range; slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137N5756 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N1061

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 132N1061

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N1061 and type code NXA03855-A0T02WG-A8A2BHBHEC+ARFIFF03+LPC2+SPXE is a 236 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136X0096

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 136X0096

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136X0096 and type code NXA03855-A0T02WG-A1A2D7B5CI is a 236 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N4988

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 132N4988

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N4988 and type code NXA03855-A0T02WG-A1A2D700CP+FL23+GRID+ARFIF106+DNOT+DLDE is a 236 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X1464

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 132X1464

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X1464 and type code NXA03855-A0T02WG-A1A20000E7+ARFIFF30 is a 236 kW, three-phase 380-500 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N2358

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 236 kW 380-500V IP00 - 132N2358

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N2358 and type code NXA03855-A0T02WG-A1A2D7BHCQ+GRDC+ARFIF106 is a 236 kW, three-phase 380-500 V...