VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H6889

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 220 kW 525-690V IP00 - 137H6889

Send inquiry Order code: 137H6889
(You save )
Brand
VACON
SKU:
137H6889
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
220
Rated current (A):
208
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH61
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA02086-G0T02WG-A8A3A50000+FL26+DLCN

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H6889 and type code NXA02086-G0T02WG-A8A3A50000+FL26+DLCN is a 220 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61 configuration. It is rated 208 A continuous output current and meets EMC category C4.

Key specifications

Order code137H6889
Type codeNXA02086-G0T02WG-A8A3A50000+FL26+DLCN
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power220 kW
Rated current208 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH61
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5715253437705

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0208208 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL26UK,RU,CN;Others
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLCNChinese
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH61Frame 61 liquid cooled
Motor Power Low Overload [kW]220220
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]246X658X374246X658X374
Continuous Current (NO) [A]189189
Continuous Current (HO) [A]--

Typical applications

At 220 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 1RO(NO/NC),1RO(NC), therm; slot C: 3DI(Enc.10-24V),15/24Vout.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137H6889 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X2776

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 220 kW 525-690V IP00 - 132X2776

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X2776 and type code NXA02086-A0T02WG-A1AFD7B2E6+FL23+GRID+ARFIF106+DLDE is a 220 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L9495

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 220 kW 525-690V IP00 - 137L9495

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L9495 and type code NXA02086-A0T02WG-A1A2D7E6E9+MASG+ARFIFF03+DLDE+GAIN is a 220 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136Z9900

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 220 kW 525-690V IP00 - 136Z9900

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136Z9900 and type code NXA02086-A0T02WG-A1AF00B2E6+FL23+GRID+ARFIF106+DLDE is a 220 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H7525

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 220 kW 525-690V IP00 - 132H7525

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H7525 and type code NXA02086-A0T02WG-A8B1D7D6CI+FL21+MASG+ARFIFF03+GSNT+LPC2+SPXE is a 220 kW,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9466

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 136L9466

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9466 and type code NXA06506-A0T02WG-A1A2B50000+FL23+GALR is a 687 kW, three-phase 525-690 V supply,...