  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 380-500 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 136N1817
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N1817
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N1817

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 136N1817

Send inquiry Order code: 136N1817
(You save )
Brand
VACON
SKU:
136N1817
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1860
Rated current (A):
2300
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA23005-A0T02WO-A8A2D7B5E9+UGRD+ARFIF106+GALR

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N1817 and type code NXA23005-A0T02WO-A8A2D7B5E9+UGRD+ARFIF106+GALR is a 1860 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH64 configuration. It is rated 2300 A continuous output current and meets EMC category C4.

Key specifications

Order code136N1817
Type codeNXA23005-A0T02WO-A8A2D7B5E9+UGRD+ARFIF106+GALR
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1860 kW
Rated current2300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5710108895174

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current23002300 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsO-IP54 ContUnit, varn/fib conn.
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot DB53RO(NO)
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software license+UGRDMicro grid license
Application+ARFIF106Grid Conv with codes NXA,NXI
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GALRLloyds register
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]18601860
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]27562756
Continuous Current (HO) [A]--

Typical applications

At 1860 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot D: 3RO(NO); slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 136N1817 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N5904

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 136N5904

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N5904 and type code NXA23005-A0T02WG-A1A30000CP is a 1860 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N1916

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 136N1916

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N1916 and type code NXA23005-A0T02WO-A8A2D7B5E9+MASG+ARFIFF03+GALR is a 1860 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1106

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 132H1106

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1106 and type code NXA23005-A0T02WG-0000000000+GSSE+GADN is a 1860 kW, three-phase 380-500 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136Z2551

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 136Z2551

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136Z2551 and type code NXA23005-A0T02WG-A8B5D7D2EC+GADN is a 1860 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L0180

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 361 kW 380-500V IP00 - 132L0180

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L0180 and type code NXA05905-A0T02WG-A1A2D700E9+MASG+ARFIFF03 is a 361 kW, three-phase 380-500 V...