VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H2273

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 137H2273

Send inquiry Order code: 137H2273
(You save )
Brand
VACON
SKU:
137H2273
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1262
Rated current (A):
2060
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA20605-A0T02WG-A1A2D7D6EA+FL23+DLDE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H2273 and type code NXA20605-A0T02WG-A1A2D7D6EA+FL23+DLDE is a 1262 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH64 configuration. It is rated 2060 A continuous output current and meets EMC category C4.

Key specifications

Order code137H2273
Type codeNXA20605-A0T02WG-A1A2D7D6EA+FL23+DLDE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1262 kW
Rated current2060 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5715253388410

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current20602060 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot DD6CAN-MonBus galv.decoupled
Option Slot EEAAdvanced 2-port ethernet
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLDEGerman
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]12621262
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]18731873
Continuous Current (HO) [A]--

Typical applications

At 1262 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot D: CAN-MonBus galv.decoupled; slot E: Advanced 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137H2273 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1105

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 132H1105

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1105 and type code NXA20605-A0T02WG-A8B500D2EC+MASG+ARFIFF03+GADN is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X0562

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 132X0562

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X0562 and type code NXA20605-A0T02WG-A8B100D2E3+ARFIFF30+GAAB is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136X1461

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 136X1461

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136X1461 and type code NXA20605-A0T02WG-A1A200CI00 is a 1262 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132X0556

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 132X0556

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132X0556 and type code NXA20605-A0T02WG-A8B100D2E3+ARFIFF03+GAAB is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N6963

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 132N6963

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N6963 and type code NXA20605-A0T02WG-A1A2D7B5CI+FL23+MASG+ARFIFF03+GALR is a 1262 kW, three-phase...