VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U7232

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137U7232

Send inquiry Order code: 137U7232
(You save )
Brand
VACON
SKU:
137U7232
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1247
Rated current (A):
1180
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA11806-A0T02PG-ANB1D7B1D2+FL23+MASG+ARFIFF03+GSNT+GAAB+LPC2+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U7232 and type code NXA11806-A0T02PG-ANB1D7B1D2+FL23+MASG+ARFIFF03+GSNT+GAAB+LPC2+SPXE is a 1247 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH64 configuration. It is rated 1180 A continuous output current and meets EMC category C4.

Key specifications

Order code137U7232
Type codeNXA11806-A0T02PG-ANB1D7B1D2+FL23+MASG+ARFIFF03+GSNT+GAAB+LPC2+SPXE
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1247 kW
Rated current1180 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,2AI,2AO,10/-10Vref,24V
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5715253757339

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationPLiquidCooled w. nickel element
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current11801180 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AAN6DI,2AI,2AO,10/-10Vref,24V
Option Slot BB16 programmableDI/DO
Option Slot CD7Line voltage meas.
Option Slot DB16 programmableDI/DO
Option Slot ED2SysBus(1fiber), CAN-MonBus
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software license+MASGGrid Converter license
Application+ARFIFF03Grid Converter NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GAABAmerican bureau shipping
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]12471247
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]10731073
Continuous Current (HO) [A]--

Typical applications

At 1247 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,2AI,2AO,10/-10Vref,24V; slot B: 6 programmableDI/DO; slot C: Line voltage meas.; slot D: 6 programmableDI/DO; slot E: SysBus(1fiber), CAN-MonBus.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137U7232 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U9359

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137U9359

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U9359 and type code NXA11806-A0T02WG-A1A20000E5+FL21+ARFIFF05+DLSE is a 1247 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H4889

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132H4889

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H4889 and type code NXA11806-A0T02WG-A1B1D7D2E9+FL23+ARFIFF03+DLDE+GALR+LPC2 is a 1247 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N0500

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132N0500

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N0500 and type code NXA11806-A0T02PG-A1A2D7B5E9+FL23+MASG+ARFIFF03+DLDE is a 1247 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N3327

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132N3327

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N3327 and type code NXA11806-A0T02WG-A1A2000000+FL23+DLNL is a 1247 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132N0503

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132N0503

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132N0503 and type code NXA11806-A0T02PG-A1A2B500E9+FL23+ARFIFF05+DLDE is a 1247 kW, three-phase 525-690 V...