  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137L7464
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L7464
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L7464

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137L7464

Send inquiry Order code: 137L7464
(You save )
Brand
VACON
SKU:
137L7464
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1247
Rated current (A):
1180
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA11806-G0T02WG-A8B10000E3+GABV

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L7464 and type code NXA11806-G0T02WG-A8B10000E3+GABV is a 1247 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH64 configuration. It is rated 1180 A continuous output current and meets EMC category C4.

Key specifications

Order code137L7464
Type codeNXA11806-G0T02WG-A8B10000E3+GABV
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1247 kW
Rated current1180 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5715253550725

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current11801180 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BB16 programmableDI/DO
Option Slot C00No board
Option Slot D00No board
Option Slot EE3PROFIBUS DP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GABVBureau Veritas
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]12471247
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]10731073
Continuous Current (HO) [A]--

Typical applications

At 1247 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 6 programmableDI/DO; slot E: PROFIBUS DP.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137L7464 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L3878

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 132L3878

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L3878 and type code NXA11806-A0T02WG-A1A200B5E9 is a 1247 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136N6678

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 136N6678

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136N6678 and type code NXA11806-A0T02WG-A1A2B5B8CP is a 1247 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H4299

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137H4299

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H4299 and type code NXA11806-A0T02PG-A1B1D700E9 is a 1247 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N8778

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137N8778

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N8778 and type code NXA11806-G0T02WG-A8A2000000 is a 1247 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L3665

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137L3665

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L3665 and type code NXA11806-A0T02WG-A1A20000E9+GSNT+EMAR+LPC2+SPXE is a 1247 kW, three-phase 525-690...