VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L6813

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 132L6813

Send inquiry Order code: 132L6813
(You save )
Brand
VACON
SKU:
132L6813
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1088
Rated current (A):
1030
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA10306-A0T02WG-A1A20000B5+FL23+DLNL

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L6813 and type code NXA10306-A0T02WG-A1A20000B5+FL23+DLNL is a 1088 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH64 configuration. It is rated 1030 A continuous output current and meets EMC category C4.

Key specifications

Order code132L6813
Type codeNXA10306-A0T02WG-A1A20000B5+FL23+DLNL
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1088 kW
Rated current1030 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5714853883547

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current10301030 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot EB53RO(NO)
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLNLDutch
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]10881088
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]936936
Continuous Current (HO) [A]--

Typical applications

At 1088 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: 3RO(NO).

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 132L6813 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H9354

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 132H9354

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H9354 and type code NXA10306-A0T02PG-ANB1D7D2E9+FL23+ARFIFF03+DLDE+GALR+LPC2 is a 1088 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U9527

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 137U9527

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U9527 and type code NXA10306-A0T02WG-A8B1D7D2E3+ARFIFF03+GADN is a 1088 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132L0763

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 132L0763

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132L0763 and type code NXA10306-A0T02WG-A1A2B5D2EA+FL23+ARFIFF05+DLDE is a 1088 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H4890

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 132H4890

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H4890 and type code NXA10306-A0T02WG-A1B1D7D2E9+FL23+ARFIFF03+DLDE+GALR+LPC2 is a 1088 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137G5725

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1088 kW 525-690V IP00 - 137G5725

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137G5725 and type code NXA10306-A0T02WG-A1A20000E9+ARFIFF05+DLES is a 1088 kW, three-phase 525-690 V...