  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus
  • VACON NXP Liquid Cooled Common DC Bus 525-690 V
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 137L9877
  • VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L9877
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L9877

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 137L9877

Send inquiry Order code: 137L9877
(You save )
Brand
VACON
SKU:
137L9877
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled Common DC Bus
Power (kW):
1070
Rated current (A):
920
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA09206-A0T02WG-A1A20000EA

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L9877 and type code NXA09206-A0T02WG-A1A20000EA is a 1070 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH64 configuration. It is rated 920 A continuous output current and meets EMC category C4.

Key specifications

Order code137L9877
Type codeNXA09206-A0T02WG-A1A20000EA
SeriesVACON® NXP Liquid Cooled Common DC Bus
Product typeLiquid-Cooled Active Front End Unit
Rated power1070 kW
Rated current920 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5715253575780

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0920920 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot EEAAdvanced 2-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Motor Power Low Overload [kW]10701070
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]746X923X375746X923X375
Continuous Current (NO) [A]10901090
Continuous Current (HO) [A]--

Typical applications

At 1070 kW, this liquid-cooled active front end unit is typically used for compact high-power multi-drive systems in marine, offshore and process industry.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: Advanced 2-port ethernet.

About the VACON NXP Liquid Cooled Common DC Bus series

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

Need this exact configuration or an alternative? Send us the order code 137L9877 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137U8962

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 137U8962

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137U8962 and type code NXA09206-A0T02WG-A1A200D200+ARFIFF30 is a 1070 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136Z4427

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 136Z4427

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136Z4427 and type code NXA09206-A0T02WG-A1A2000000 is a 1070 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L5331

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 136L5331

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L5331 and type code NXA09206-A0T02WG-A8A20000CI is a 1070 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L3471

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 136L3471

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L3471 and type code NXA09206-A0T02WG-A1A20000E9 is a 1070 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136H2116

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 136H2116

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136H2116 and type code NXA09206-A0T02WG-A100000000 is a 1070 kW, three-phase 525-690 V supply, IP00...