VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136N2818

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 136N2818

Send inquiry Order code: 136N2818
(You save )
Brand
VACON
SKU:
136N2818
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled
Power (kW):
600
Rated current (A):
1150
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP11505-A0N0SWG-A1A2B20000

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136N2818 and type code NXP11505-A0N0SWG-A1A2B20000 is a 600 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63 configuration. It is rated 1150 A continuous output current and meets EMC category C4.

Key specifications

Order code136N2818
Type codeNXP11505-A0N0SWG-A1A2B20000
SeriesVACON® NXP Liquid Cooled
Product typeLiquid-Cooled AC Drive
Rated power600 kW
Rated current1150 A
Current, high overload1030 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5710108906320

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current11501150 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsNno EMC protection
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CB21RO(NO/NC),1RO(NO),therm
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Power rating600600 kW
Motor Power Low Overload [kW]600600
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]11501150
Continuous Current (HO) [A]10301030

Typical applications

At 600 kW, this liquid-cooled ac drive is typically used for marine propulsion and thrusters, offshore drilling, mining and heavy industry where space is limited or air cooling is difficult.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 1RO(NO/NC),1RO(NO),therm.

About the VACON NXP Liquid Cooled series

VACON® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

Need this exact configuration or an alternative? Send us the order code 136N2818 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0883

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 137H0883

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0883 and type code NXP11505-A0T0IWG-A1AFA5B8E9+APFIFF09+GSSE is a 600 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132H3778

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 132H3778

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132H3778 and type code NXP11505-A0N0NWG-A1A20000CQ is a 600 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136U3765

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 136U3765

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136U3765 and type code NXP11505-A0N0NWG-A1AF0000CQ+APAUQ010 is a 600 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136N1894

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 136N1894

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136N1894 and type code NXP11505-A0T0IWO-A8A2A5B5E9+GALR is a 600 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G5485

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 137G5485

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G5485 and type code NXP11505-A0T0IWG-A1A200D2E6+FL23+DLDE+LPC2 is a 600 kW, three-phase 380-500 V supply, IP00 enclosure, frame...