  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled
  • VACON NXP Liquid Cooled 380-500 V
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 132N0850
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132N0850
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132N0850

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 132N0850

Send inquiry Order code: 132N0850
(You save )
Brand
VACON
SKU:
132N0850
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled
Rated current (A):
590
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH62
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP05905-A0T0IPG-A8A3A5B500

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132N0850 and type code NXP05905-A0T0IPG-A8A3A5B500 is a 590 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62 configuration. It is rated 590 A continuous output current and meets EMC category C4.

Key specifications

Order code132N0850
Type codeNXP05905-A0T0IPG-A8A3A5B500
SeriesVACON® NXP Liquid Cooled
Product typeLiquid-Cooled AC Drive
Rated current590 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH62
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)658 x 246 x 374 mm
Net weight55 kg
EAN5715253046501

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationPLiquidCooled w. nickel element
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0590590 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationIINU, no charging circuit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DB53RO(NO)
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH62Frame 62 liquid cooled
Dimensions WxHxD [mm]246X658X374246X658X374

Typical applications

This configuration, this liquid-cooled ac drive is typically used for marine propulsion and thrusters, offshore drilling, mining and heavy industry where space is limited or air cooling is difficult.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 1RO(NO/NC),1RO(NC), therm; slot C: 3DI(Enc.10-24V),15/24Vout; slot D: 3RO(NO).

About the VACON NXP Liquid Cooled series

VACON® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

Need this exact configuration or an alternative? Send us the order code 132N0850 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132H5171

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 132H5171

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132H5171 and type code NXP05905-A0T0IWG-A1A2BCBHE6+APFIFF09 is a 590 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N3256

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 137N3256

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N3256 and type code NXP05905-A0T0IWG-A1A2A500E7+ARFIFF30 is a 590 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132H8099

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 132H8099

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132H8099 and type code NXP05905-A0T0IWG-A1A2BC00E9 is a 590 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H4307

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 137H4307

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H4307 and type code NXP05905-A0T0IWG-A1AFBCBHE7+APFIFF09 is a 590 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132X1371

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 590 A 380-500V IP00 - 132X1371

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132X1371 and type code NXP05905-G0T0IWG-A1A2000000+FL26+DLCN+GACS is a 590 A, three-phase 380-500 V supply, IP00 enclosure, frame...