  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled
  • VACON NXP Liquid Cooled 380-500 V
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137U7930
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U7930
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U7930

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137U7930

Send inquiry Order code: 137U7930
(You save )
Brand
VACON
SKU:
137U7930
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled
Power (kW):
450
Rated current (A):
820
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH63
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP08205-A0T0IWG-A1AF0000E9+GSNT+EMAR+LPC2+SPXE

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U7930 and type code NXP08205-A0T0IWG-A1AF0000E9+GSNT+EMAR+LPC2+SPXE is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63 configuration. It is rated 820 A continuous output current and meets EMC category C4.

Key specifications

Order code137U7930
Type codeNXP08205-A0T0IWG-A1AF0000E9+GSNT+EMAR+LPC2+SPXE
SeriesVACON® NXP Liquid Cooled
Product typeLiquid-Cooled AC Drive
Rated power450 kW
Power, high overload400 kW
Rated current820 A
Current, high overload547 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH63
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)923 x 505 x 375 mm
Net weight120 kg
EAN5715253764429

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0820820 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationIINU, no charging circuit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot C00No board
Option Slot D00No board
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+EMARMarine Approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH63Frame 63 liquid cooled
Motor Power Low Overload [kW]450450
Motor Power High Overload [kW]400400
Dimensions WxHxD [mm]505X923X375505X923X375
Continuous Current (NO) [A]745745
Continuous Current (HO) [A]547547
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 450 kW, this liquid-cooled ac drive is typically used for marine propulsion and thrusters, offshore drilling, mining and heavy industry where space is limited or air cooling is difficult.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 400 kW / 547 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot E: 2-port ethernet.

About the VACON NXP Liquid Cooled series

VACON® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

Need this exact configuration or an alternative? Send us the order code 137U7930 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136L4649

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 136L4649

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136L4649 and type code NXP07305-A0N0SPG-A1A2B400CI+FL25+LS60 is a 450 kW (600 HP), three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136X1867

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 136X1867

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136X1867 and type code NXP07305-A0T0SWG-A1A20000E9+APFIFF09 is a 450 kW (600 HP), three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136Z8215

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 136Z8215

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136Z8215 and type code NXP08205-A0N0SWG-A1AFA500E9+FL23+DLNL is a 450 kW (600 HP), three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H2168

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137H2168

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H2168 and type code NXP08205-A0T0SWG-A1AF00B5E6+APFIFF09 is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N8274

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137N8274

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N8274 and type code NXP08205-A0T0IWG-A1A2BC00E9+ARFIFF30+DLFR+GALR is a 450 kW, three-phase 380-500 V supply, IP00 enclosure,...