  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled
  • VACON NXP Liquid Cooled 380-500 V
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 137L9905
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9905
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9905

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 137L9905

Send inquiry Order code: 137L9905
(You save )
Brand
VACON
SKU:
137L9905
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled
Rated current (A):
2060
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH64
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP20605-A0T0IWG-A8B5A5D2EC+GALR

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9905 and type code NXP20605-A0T0IWG-A8B5A5D2EC+GALR is a 2060 A, three-phase 380-500 V supply, IP00 enclosure, frame CH64 configuration. It is rated 2060 A continuous output current and meets EMC category C4.

Key specifications

Order code137L9905
Type codeNXP20605-A0T0IWG-A8B5A5D2EC+GALR
SeriesVACON® NXP Liquid Cooled
Product typeLiquid-Cooled AC Drive
Rated current2060 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH64
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)923 x 746 x 375 mm
Net weight180 kg
EAN5715253576077

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current20602060 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationIINU, no charging circuit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BB53RO(NO)
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot EECEtherCAT
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GALRLloyds register
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH64Frame 64 liquid cooled
Dimensions WxHxD [mm]746X923X375746X923X375

Typical applications

This configuration, this liquid-cooled ac drive is typically used for marine propulsion and thrusters, offshore drilling, mining and heavy industry where space is limited or air cooling is difficult.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 3RO(NO); slot C: 3DI(Enc.10-24V),15/24Vout; slot D: SysBus(1fiber), CAN-MonBus; slot E: EtherCAT.

About the VACON NXP Liquid Cooled series

VACON® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

Need this exact configuration or an alternative? Send us the order code 137L9905 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G1859

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 137G1859

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G1859 and type code NXP20605-G0T0IWG-A8A2BH00E9+DCD1+ADFIF101+GSNT+LPC2+SPXE is a 2060 A, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G5904

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 137G5904

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G5904 and type code NXP20605-A0T0IWG-0000000000+GSSE+GALR is a 2060 A, three-phase 380-500 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L2128

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 137L2128

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L2128 and type code NXP20605-A0T0IWG-A8B1B1B4E9 is a 2060 A, three-phase 380-500 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132X9118

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 132X9118

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132X9118 and type code NXP20605-A0T0IWG-A8B5A5D2EC+GADN is a 2060 A, three-phase 380-500 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132X4217

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2060 A 380-500V IP00 - 132X4217

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132X4217 and type code NXP20605-A0T0IWG-A1AFA500E9+FL21+APFIFF09+DLNL is a 2060 A, three-phase 380-500 V supply, IP00 enclosure,...