<
<
  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled
  • VACON NXP Liquid Cooled 380-500 V
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 137N3888
  • VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N3888
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N3888

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 137N3888

Send inquiry Order code: 137N3888
(You save )
Brand
VACON
SKU:
137N3888
UPC:
Condition:
New
Series:
VACON NXP Liquid Cooled
Power (kW):
1250
Rated current (A):
2300
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
CH74
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP23005-A0T0NWG-A1A2A5B4D2+DNOT

Adding to cart… The item has been added

Description

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N3888 and type code NXP23005-A0T0NWG-A1A2A5B4D2+DNOT is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH74 configuration. It is rated 2300 A continuous output current and meets EMC category C4.

Key specifications

Order code137N3888
Type codeNXP23005-A0T0NWG-A1A2A5B4D2+DNOT
SeriesVACON® NXP Liquid Cooled
Product typeLiquid-Cooled AC Drive
Rated power1250 kW
Power, high overload1100 kW
Rated current2300 A
Current, high overload1533 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeCH74
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1175 x 746 x 375 mm
Net weight280 kg
EAN5715253617312

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationWLiquid cooling
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current23002300 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationN6-puls No choke for Spare unit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DB4AI,2AO(mA,isol),+24V/EXT
Option Slot ED2SysBus(1fiber), CAN-MonBus
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DNOTNo manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeCH74Frame 74 liquid cooled
Motor Power Low Overload [kW]12501250
Motor Power High Overload [kW]11001100
Dimensions WxHxD [mm]746X1175X375746X1175X375
Continuous Current (NO) [A]20912091
Continuous Current (HO) [A]15331533

Typical applications

At 1250 kW, this liquid-cooled ac drive is typically used for marine propulsion and thrusters, offshore drilling, mining and heavy industry where space is limited or air cooling is difficult.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 1100 kW / 1533 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 3DI(Enc.10-24V),15/24Vout; slot D: 2AO(mA,isol),+24V/EXT; slot E: SysBus(1fiber), CAN-MonBus.

About the VACON NXP Liquid Cooled series

VACON® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

Need this exact configuration or an alternative? Send us the order code 137N3888 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136Z2552

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 136Z2552

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136Z2552 and type code NXP23005-A0T0IWG-A8B500D2EC+GADN is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L1989

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 137L1989

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L1989 and type code NXP23005-A0T1NWG-A1AFBCBHE6 is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH74...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136Z6901

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 136Z6901

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136Z6901 and type code NXP23005-A0T0IWG-A8B5A5D2EC+GADN is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132X0236

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 132X0236

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 132X0236 and type code NXP23005-A0T0NWG-A1A2A5B4D2 is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH74...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 136N1893

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 136N1893

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 136N1893 and type code NXP23005-A0T0IWO-A8A2A5B5E9+GALR is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH64...