VACON NXP Grid Converter Active Front End Unit 136N4621

VACON NXP Grid Converter Active Front End Unit 310 kW 380-500V IP00 - 136N4621

Send inquiry Order code: 136N4621
(You save )
Brand
VACON
SKU:
136N4621
UPC:
Condition:
New
Series:
VACON NXP Grid Converter
Power (kW):
310
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA03855-A0T02SG-A1A2D700CI+MASG+ARFIFF03

Adding to cart… The item has been added

Description

The VACON NXP Grid Converter active front end unit with order code 136N4621 and type code NXA03855-A0T02SG-A1A2D700CI+MASG+ARFIFF03 is a 310 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code136N4621
Type codeNXA03855-A0T02SG-A1A2D700CI+MASG+ARFIFF03
SeriesVACON® NXP Grid Converter
Product typeActive Front End Unit
Rated power310 kW
Rated current385 A
Current, high overload300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1032 x 239 x 552 mm
Net weight100 kg
EAN5710108924928

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot ECIModbus/TCP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software license+MASGGrid Converter license
Application+ARFIFF03Grid Converter NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI10Frame 10 INU
Motor Power Low Overload [kW]310310
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1032X552239X1032X552
Continuous Current (NO) [A]456456
Continuous Current (HO) [A]300300

Typical applications

At 310 kW, this active front end unit is typically used for shore power, micro-grids, renewable energy and hybrid marine power systems.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot E: Modbus/TCP.

About the VACON NXP Grid Converter series

VACON® NXP Grid Converters connect generators, energy storage and renewable sources to the grid or to an island network. They control voltage and frequency, support shore connection and micro-grids, and keep harmonic distortion low.

Need this exact configuration or an alternative? Send us the order code 136N4621 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Grid Converter Active Front End Unit 136X6378

VACON 

VACON NXP Grid Converter Active Front End Unit 310 kW 380-500V IP00 - 136X6378

The VACON NXP Grid Converter active front end unit with order code 136X6378 and type code NXA03855-A0T02SG-A1A2D700E9+FL23+MASG+ARFIFF03+DLNL is a 310 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter Active Front End Unit 137G1436

VACON 

VACON NXP Grid Converter Active Front End Unit 310 kW 380-500V IP00 - 137G1436

The VACON NXP Grid Converter active front end unit with order code 137G1436 and type code NXA03855-A0T02SG-0000000000+MASG+ARFIFF03+DLNL+EMAR is a 310 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter Active Front End Unit 136X1247

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 136X1247

The VACON NXP Grid Converter active front end unit with order code 136X1247 and type code NXA02615-A0T02SG-A8B1D7B1E9+FL23+MASG+ARFIFF03+GALR is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter Active Front End Unit 132N9777

VACON 

VACON NXP Grid Converter Active Front End Unit 114 kW 380-500V IP00 - 132N9777

The VACON NXP Grid Converter active front end unit with order code 132N9777 and type code NXA01685-A0T02SG-A1A2D700E6+MASG+ARFIFF03 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter Active Front End Unit 137G3476

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 137G3476

The VACON NXP Grid Converter active front end unit with order code 137G3476 and type code NXA02615-A0T02SG-A8A2D700EA+MASG+ARFIFF03+GACS is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...