  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Grid Converter
  • VACON NXP Grid Converter 380-500 V
  • VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 137G1492
  • VACON NXP Grid Converter Active Front End Unit 137G1492
VACON NXP Grid Converter Active Front End Unit 137G1492

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 137G1492

Send inquiry Order code: 137G1492
(You save )
Brand
VACON
SKU:
137G1492
UPC:
Condition:
New
Series:
VACON NXP Grid Converter
Power (kW):
175
Rated current (A):
261
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI09
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA02615-A0T02SG-A1A2D700E6+MASG+ARFIFF03

Adding to cart… The item has been added

Description

The VACON NXP Grid Converter active front end unit with order code 137G1492 and type code NXA02615-A0T02SG-A1A2D700E6+MASG+ARFIFF03 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It is rated 261 A continuous output current and meets EMC category C4.

Key specifications

Order code137G1492
Type codeNXA02615-A0T02SG-A1A2D700E6+MASG+ARFIFF03
SeriesVACON® NXP Grid Converter
Product typeActive Front End Unit
Rated power175 kW
Rated current261 A
Current, high overload205 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI09
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 372 mm
Net weight67 kg
EAN5715253274188

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0261261 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot EE6CANopen
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software license+MASGGrid Converter license
Application+ARFIFF03Grid Converter NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI09Frame 09 INU
Motor Power Low Overload [kW]175175
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X372239X1030X372
Continuous Current (NO) [A]261261
Continuous Current (HO) [A]205205

Typical applications

At 175 kW, this active front end unit is typically used for shore power, micro-grids, renewable energy and hybrid marine power systems.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot E: CANopen.

About the VACON NXP Grid Converter series

VACON® NXP Grid Converters connect generators, energy storage and renewable sources to the grid or to an island network. They control voltage and frequency, support shore connection and micro-grids, and keep harmonic distortion low.

Need this exact configuration or an alternative? Send us the order code 137G1492 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Grid Converter Active Front End Unit 136L8736

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 136L8736

The VACON NXP Grid Converter active front end unit with order code 136L8736 and type code NXA02615-A0T02SG-A1A2000000+MASG+ARFIFF03 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter Active Front End Unit 137N0060

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 137N0060

The VACON NXP Grid Converter active front end unit with order code 137N0060 and type code NXA02615-A0T02SG-A1A2D7B5E9+MASG+ARFIFF03+LPC2 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Grid Converter Active Front End Unit 137G3476

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 137G3476

The VACON NXP Grid Converter active front end unit with order code 137G3476 and type code NXA02615-A0T02SG-A8A2D700EA+MASG+ARFIFF03+GACS is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Grid Converter Active Front End Unit 136X1247

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 136X1247

The VACON NXP Grid Converter active front end unit with order code 136X1247 and type code NXA02615-A0T02SG-A8B1D7B1E9+FL23+MASG+ARFIFF03+GALR is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter Active Front End Unit 136X7436

VACON 

VACON NXP Grid Converter Active Front End Unit 175 kW 380-500V IP00 - 136X7436

The VACON NXP Grid Converter active front end unit with order code 136X7436 and type code NXA02615-A0T02SG-A1A2D700CI+MASG+ARFIFF03 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...