VACON NXP Common DC Bus Active Front End Unit 136U7382

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136U7382

Send inquiry Order code: 136U7382
(You save )
Brand
VACON
SKU:
136U7382
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
773
Rated current (A):
1150
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI13
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA11505-A0T02SG-A1A2B50000

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 136U7382 and type code NXA11505-A0T02SG-A1A2B50000 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13 configuration. It is rated 1150 A continuous output current and meets EMC category C4.

Key specifications

Order code136U7382
Type codeNXA11505-A0T02SG-A1A2B50000
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power773 kW
Rated current1150 A
Current, high overload1030 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI13
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 708 x 553 mm
Net weight306 kg
EAN5714853054695

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current11501150 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CB53RO(NO)
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI13Frame 13 INU
Motor Power Low Overload [kW]773773
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]708X1030X553708X1030X553
Continuous Current (NO) [A]13551355
Continuous Current (HO) [A]10301030

Typical applications

At 773 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 3RO(NO).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136U7382 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 136U5352

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136U5352

The VACON NXP Common DC Bus active front end unit with order code 136U5352 and type code NXA11505-A0T02SG-A1A200B500+DLCN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136U4136

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136U4136

The VACON NXP Common DC Bus active front end unit with order code 136U4136 and type code NXA11505-G0T02SG-A1A30000E9+FL26+DLRU is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136H2327

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136H2327

The VACON NXP Common DC Bus active front end unit with order code 136H2327 and type code NXA11505-A0T02SG-A1A2B50000+DLCN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136U8307

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136U8307

The VACON NXP Common DC Bus active front end unit with order code 136U8307 and type code NXA11505-A0T02SG-A1A200B9CP is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136Z2423

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136Z2423

The VACON NXP Common DC Bus active front end unit with order code 136Z2423 and type code NXA11505-A0T02SG-A1A2D7B1D2+GADN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...