VACON NXP Common DC Bus Brake Chopper Unit 136N6185

VACON NXP Common DC Bus Brake Chopper Unit 75 kW 525-690V IP21 - 136N6185

Send inquiry Order code: 136N6185
(You save )
Brand
VACON
SKU:
136N6185
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
75
Rated current (A):
80
Mains voltage:
525-690 V
Enclosure:
IP21
Frame size:
FR08
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB00806-A2T08SV-A8A2000000

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 136N6185 and type code NXB00806-A2T08SV-A8A2000000 is a 75 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It is rated 80 A continuous output current and meets EMC category C4.

Key specifications

Order code136N6185
Type codeNXB00806-A2T08SV-A8A2000000
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power75 kW
Power, high overload55 kW
Rated current80 A
Current, high overload62 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
EnclosureIP21/NEMA1
Frame sizeFR08
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)758 x 288 x 344 mm
Net weight58 kg
EAN5710108940461

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current008080 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]7575
Motor Power High Overload [kW]5555
Dimensions WxHxD [mm]288X758X344288X758X344
Continuous Current (NO) [A]8080
Continuous Current (HO) [A]6262

Typical applications

At 75 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • For heavy-duty use with high overload the rating is 55 kW / 62 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136N6185 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 136N6488

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 75 kW 525-690V IP21 - 136N6488

The VACON NXP Common DC Bus brake chopper unit with order code 136N6488 and type code NXB00806-A2T08SV-A8A200CI00 is a 75 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration...
VACON NXP Common DC Bus Brake Chopper Unit 137G5321

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 137G5321

The VACON NXP Common DC Bus brake chopper unit with order code 137G5321 and type code NXB00526-A2T08SV-A8A20000E9+QGLM+GANK+LPC2+SPXE is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137H7837

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 137H7837

The VACON NXP Common DC Bus brake chopper unit with order code 137H7837 and type code NXB00076-A2T08SV-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132H7777

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 132H7777

The VACON NXP Common DC Bus brake chopper unit with order code 132H7777 and type code NXB01006-A2T08SV-A1A20000CP is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 136G9022

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 22 kW 525-690V IP21 - 136G9022

The VACON NXP Common DC Bus brake chopper unit with order code 136G9022 and type code NXB00276-A2T08SV-A1A2000000 is a 22 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06 configuration...