  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 525-690 V
  • VACON NXP Common DC Bus Active Front End Unit 378 kW 525-690V IP00 - 136X2236
  • VACON NXP Common DC Bus Active Front End Unit 136X2236
VACON NXP Common DC Bus Active Front End Unit 136X2236

VACON NXP Common DC Bus Active Front End Unit 378 kW 525-690V IP00 - 136X2236

Send inquiry Order code: 136X2236
(You save )
Brand
VACON
SKU:
136X2236
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
378
Rated current (A):
325
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FI10
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA03256-G0T02SG-A1A2D7D2B5

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 136X2236 and type code NXA03256-G0T02SG-A1A2D7D2B5 is a 378 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It is rated 325 A continuous output current and meets EMC category C4.

Key specifications

Order code136X2236
Type codeNXA03256-G0T02SG-A1A2D7D2B5
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power378 kW
Rated current325 A
Current, high overload261 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI10
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1032 x 239 x 552 mm
Net weight100 kg
EAN5714853103980

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0325325 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot EB53RO(NO)
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI10Frame 10 INU
Motor Power Low Overload [kW]378378
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1032X552239X1032X552
Continuous Current (NO) [A]385385
Continuous Current (HO) [A]261261

Typical applications

At 378 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot D: SysBus(1fiber), CAN-MonBus; slot E: 3RO(NO).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136X2236 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 136N6016

VACON 

VACON NXP Common DC Bus Active Front End Unit 378 kW 525-690V IP00 - 136N6016

The VACON NXP Common DC Bus active front end unit with order code 136N6016 and type code NXA03256-A0T02SG-A1A2D700E9+ARFIF106+DLFR is a 378 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136U8446

VACON 

VACON NXP Common DC Bus Active Front End Unit 378 kW 525-690V IP00 - 136U8446

The VACON NXP Common DC Bus active front end unit with order code 136U8446 and type code NXA03256-A0T02SO-A1A2000000+FL25+LS60+DLBR is a 378 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136U7191

VACON 

VACON NXP Common DC Bus Active Front End Unit 378 kW 525-690V IP00 - 136U7191

The VACON NXP Common DC Bus active front end unit with order code 136U7191 and type code NXA03256-A0T02SG-A8A2B500E9+DLFR is a 378 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136X6769

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 136X6769

The VACON NXP Common DC Bus active front end unit with order code 136X6769 and type code NXA09206-G0T02SG-A1A2000000 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136X3878

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136X3878

The VACON NXP Common DC Bus active front end unit with order code 136X3878 and type code NXA01256-G0T02SG-A1A2D700E9+FL25+GRID+ARFIF106+LS60 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure,...