<
<
  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 525-690 V
  • VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132L3442
  • VACON NXP Common DC Bus Active Front End Unit 132L3442
VACON NXP Common DC Bus Active Front End Unit 132L3442

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132L3442

Send inquiry Order code: 132L3442
(You save )
Brand
VACON
SKU:
132L3442
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
377
Rated current (A):
325
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FI10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA03256-A0T02SG-A1A2D7B5E9+GSNT+DLFR+LPC2+SPXV

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 132L3442 and type code NXA03256-A0T02SG-A1A2D7B5E9+GSNT+DLFR+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It is rated 325 A continuous output current and meets EMC category C4.

Key specifications

Order code132L3442
Type codeNXA03256-A0T02SG-A1A2D7B5E9+GSNT+DLFR+LPC2+SPXV
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power377 kW
Rated current325 A
Current, high overload261 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 552 mm
Net weight100 kg
EAN5714853428700

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0325325 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSNTWithout packaging
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot DB53RO(NO)
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLFRFrench
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC2Two sets of product labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI10Frame 10 INU
Motor Power Low Overload [kW]377377
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X552239X1030X552
Continuous Current (NO) [A]325325
Continuous Current (HO) [A]261261

Typical applications

At 377 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot D: 3RO(NO); slot E: 2-port ethernet.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 132L3442 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 137U7330

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137U7330

The VACON NXP Common DC Bus active front end unit with order code 137U7330 and type code NXA03256-A0T02SG-A1A2B500E5+DLDE is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G1594

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137G1594

The VACON NXP Common DC Bus active front end unit with order code 137G1594 and type code NXA03256-A0T02SG-A1A2000000+FL23+GSNT+DLDE+LPC2+SPXE is a 377 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137N0854

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N0854

The VACON NXP Common DC Bus active front end unit with order code 137N0854 and type code NXA03256-A0T02SG-A1A2D7D2EC+FL24+GRID+ARFIF106+DLPL is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H3222

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137H3222

The VACON NXP Common DC Bus active front end unit with order code 137H3222 and type code NXA03256-G0T02SG-A1A2000000+ARFIF106 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132H6018

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132H6018

The VACON NXP Common DC Bus active front end unit with order code 132H6018 and type code NXA03256-A0T02SG-A1A2B50000+FL25+GSNT+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...